INSTALLATION REQUIREMENTS

Tools and Parts

Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here.

Tools needed

Tape measure

Marker or pencil

Flat-blade screwdriver

Pliers

Phillips head screwdriver

¼" drill bit

Drill

Jigsaw

Level

Ratchet with ³⁄₈"socket

6" socket extension

Parts supplied

Vent grille

Pre-filter

Parts needed

A UL listed or CSA approved strain relief for ⁷⁄₈" (2.2 cm)

knockout.

A UL listed or CSA approved conduit connector for

¹⁄₂" (1.3 cm) trade-size metal-clad conduit

UL listed wire connectors

Metal ducting

Jenn-Air wall cap

Jenn-Air®6" (15.2 cm) Round Surface Wall Cap Damper

Order Part Number A406

Jenn-Air®3¼" x 10" (8.3 x 25.4 cm) Surface Wall Cap Damper

Location Requirements

IMPORTANT: Observe all governing codes and ordinances. When installing cooktop, use minimum dimensions given.

To eliminate the risk of burns or fire by reaching over the heated surface units, cabinet storage space located above the surface units should be avoided. If cabinet storage is to be provided, the risk can be reduced by installing a range hood that projects horizontally a minimum of 5" (12.7 cm) beyond the bottom of the cabinets.

Use the countertop opening dimensions that are given with these Installation Instructions. Given dimensions are minimum clearances and provide 0" (0 cm) clearance.

Grounded electrical supply is required. See “Electrical Requirements” section.

If cabinet has drawers, drawers will need to be removed and drawer fronts installed on front of cabinet.

IMPORTANT: An under-counter built-in oven cannot be installed under this product.

Product Dimensions

30" (76.2 cm) Cooktop - for standard and electric models

Order Part Number A403

To order, see the “Assistance or Service” section of the Use

and Care Guide.

Vent clamps

B

A

C

Check local codes. Check existing electrical supply. See “Electrical Requirements” section.

It is recommended that all electrical connections be made by a licensed, qualified electrical installer.

A. Model/serial rating plate location B. 20⁹⁄₁₆" (52.3 cm)

C. 22" (55.9 cm)

3

Page 3
Image 3
Jenn-Air W10197059B installation instructions Installation Requirements, Tools and Parts, Location Requirements