Concrete Slab Installations - Exhaust Through Window Well

Calculating Vent System Length

A

BD

C

E

F G

H

To calculate the length of the system you need, add the equivalent feet (meters) for each vent piece used in the system.

Vent Piece

6" (15.2 cm) Round

45° elbow

2.5 ft

 

(0.8 m)

N

M

K

L

I

J

90° elbow

5.0 ft

 

(1.5 m)

A. Wall cap

B. 12" (30.5 cm) minimum C. Concrete slab

D. 6" (15.2 cm) round PVC sewer pipe

E. 5" to 6" (12.7 cm to 15.2 cm) transition F. 6" (15.2 cm) round metal duct

G. 6" (15.2 cm) round PVC coupling H. 6" (15.2 cm) round PVC sewer pipe

I. 6" (15.2 cm) round 90° PVC sewer pipe elbow

J. Tightly pack gravel or sand completely around pipe. K. 42 ft (12.8 m) max.

L. 6" (15.2 cm) round PVC coupling M. 6" (15.2 cm) minimum

N. Window well

Concrete Slab Installations - Exhaust Through Wall

B

6" (15.2 cm)

0.0 ft

wall cap

(0.0 m)

 

 

3¹⁄₄" x 10" (8.3 cm x 25.4 cm)

4.5 ft

to 6" (15.2 cm) transition

(1.4 m)

 

 

6" (15.2 cm) to 3¹⁄₄" x 10"

1 ft

(8.3 cm x 25.4 cm) transition

(0.3 m)

A

O

N

M

D

C

L

E

F

G

H I

J

K

3¹⁄₄" x 10" (8.3 cm x 25.4 cm)

9.0 ft

to 6" (15.2 cm) 90° elbow

(2.7 m)

transition

 

 

 

6" (15.2 cm) to 3¹⁄₄" x 10"

5.0 ft

(8.3 cm x 25.4 cm) 90° elbow

(1.5 m)

transition

 

 

 

3¹⁄₄" x 10" (8.3 cm x 25.4 cm)

5.0 ft

A. Wall cap

B. 6" (15.2 cm) round metal vent C. 16" (40.6 cm) maximum

D. 6" (15.2 cm) round PVC sewer pipe

E. 5" to 6" (12.7 cm to 15.2 cm) transition F. 6" (15.2 cm) round metal duct

G. 6" (15.2 cm) round PVC coupling H. Concrete slab

I. 6" (15.2 cm) round PVC sewer pipe

J. 6" (15.2 cm) round 90° PVC sewer pipe elbow

K. Tightly pack gravel or sand completely around pipe. L. 30 ft (9.1 m) max.

M. 6" (15.2 cm) round 90° PVC sewer pipe elbow N. 6" (15.2 cm) round PVC coupling

O. 12" (30.5 cm) minimum

90° elbow

(1.5 m)

 

 

3¹⁄₄" x 10" (8.3 cm x 25.4 cm)

12.0 ft

flat elbow

(3.7 m)

 

 

3¹⁄₄" x 10" (8.3 cm x 25.4 cm)

0.0 ft

wall cap

(0.0 m)

 

 

5" to 6" (12.7 cm to 15.2 cm)

1 ft

transition

(0.3 m)

 

 

6

Page 6
Image 6
Jenn-Air W10298937B Calculating Vent System Length, Concrete Slab Installations Exhaust Through Wall, Vent Piece Cm Round