PRODUCT DATA SHEETS

Base Grille Water Filtration System

Model WF-L200V Capacity 200 Gallons (757 Liters)

Model WF-NL120V Capacity 120 Gallons (454 Liters))

Tested and certified by NSF International against ANSI/NSF Standard 42 for the reduction of Chlorine, Taste and Odor, Particulate Class lll*; and against ANSI/NSF Standard 53 for the reduction of Lead, Mercury, Benzene, and p-dichlorobenzene.

This system has been tested according to ANSI/NSF 42/53 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in ANSI/NSF 42/53.

Substance Reduction

NSF Reduction

Average

Influent Challenge

Maximum

Average

Minimum %

Average %

Aesthetic Effects

Requirements

Influent

Concentration

Effluent

Effluent

Reduction

Reduction

 

 

 

 

 

 

 

 

Chlorine Taste/Odor

50%

1.9 mg/L

2.0 mg/L ± 10%

0.07 mg/L

0.06 mg/L

>75.0%

>75.0%

Particulate Class III*

85%

49,333/mL

At least 10,000 particles/mL

640 mg/L**

312 mg/L

98.7%

99%

 

 

 

 

 

 

 

 

Contaminant

NSF Reduction

Average

Influent Challenge

Maximum

Average

Minimum %

Average %

Reduction

Requirements

Influent

Concentration

Effluent

Effluent

Reduction

Reduction

 

 

 

 

 

 

 

 

Lead: @ pH 6.5

0.01mg/L

0.14 mg/L***

0.15 mg/L ± 10%

0.0014 mg/L

0.0011 mg/L

99.0%

99.21%

Lead: @ pH 8.5

0.01mg/L

0.15 mg/L***

0.15 mg/L ± 10%

0.0069 mg/L

0.0042 mg/L

95.4%

97.08%

 

 

 

 

 

 

 

 

Mercury: @ pH 6.5

0.002 mg/L

0.0059 mg/L

0.006 mg/L ± 10%

0.0009 mg/L

0.0004 mg/L

84.74%

92.47%

Mercury: @ pH 8.5

0.002 mg/L

0.0054 mg/L

0.006 mg/L ± 10%

0.0007 mg/L

0.00043 mg/L

87.03%

91.93%

 

 

 

 

 

 

 

 

Benzene

0.0050 mg/L

0.0157 mg/L

0.015 ± 10%

0.002 mg/L

0.00083 mg/L

87.26%

94.71%

 

 

 

 

 

 

 

 

p-dichlorobenzene

0.075 mg/L

0.210 mg/L

0.225 ± 10%

0.0005 mg/L

0.0005 mg/L

99.76%

99.76%

 

 

 

 

 

 

 

 

Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 63°F (17.2°C).

It is essential that operational, maintenance, and filter replacement requirements be carried out for the product to perform as advertised.

Model WF-L200V:The filter monitor system measures the amount of water that passes through the filter and alerts you to replace the filter. When 90% of the filter’s rated life is used, the filter indicator light changes from green to yellow. When 100% of the filter’s rated life is used, the filter indicator light changes from yellow to red, and it is recommended that you replace the filter. Use replacement cartridge L200V / NL120V, part #4396702. 2010 suggested retail price of $32.99 U.S.A./ $49.99 Canada. Prices are subject to change without notice.

Model WF-NL120V:Change the water filter cartridge every 6- 9 months. Use replacement cartridge L200V / NL120V, part #4396702. 2010 suggested retail price of $32.99 U.S.A./ $49.99 Canada. Prices are subject to change without notice.

The product is for cold water use only.

Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.

Refer to the front cover or “Accessories” section for the Manufacturer’s name, address and telephone number.

Refer to the “Warranty” section for the Manufacturer’s limited warranty.

Application Guidelines/Water Supply Parameters

Water Supply

City or Well

Water Pressure

30 - 120 psi (207 - 827 kPa)

Water Temperature

33° - 100°F (0.6° - 37.8° C)

Service Flow Rate

0.5 GPM (1.89 L/min.) @ 60 psi.

 

 

*Class III particle size: >5 to <15 um

**Test requirement is at least 10,000 particles/mL of AC Fine Test Dust.

***These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions. ® NSF is a registered trademark of NSF International.