WARNING

Electrical Shock Hazard

Electrically ground dishwasher.

Connect ground wire to green ground connector in terminal box.

Do not use an extension cord.

Failure to follow these instructions can result in death, fire, or electrical shock.

Remove the green grounding screw and place through the ring terminal of the green ground wire. Reattach and tighten the green screw.

NOTE: Do not pre-twist stranded wire. Twist on wire connector. Gently tug on wires to be sure both are secured.

Connect wires black to black and white to white, using UL Listed/CSA Approved twist-on wire connectors.

If needed, see website for animated representation of this step. Visit www.jenn-air.com/electricalunder FAQ tab.

Tighten strain relief screws to secure cord.

Place wires inside terminal box. Insert tabs on left side of cover. Make sure wires are tucked inside box. Close cover ensuring wires are not pinched. Use ¹⁄₄" nut driver or Torx® T20® screwdriver and previously removed screw to secure cover.

NOTE: Do not plug into outlet until instructed to do so.

13

Page 13
Image 13
Jenn-Air W10418362B installation instructions