Make Electrical Connection
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use 8 gauge copper wire.
Electrically ground cooktop.
Failure to follow these instructions can result in death, fire, or electrical shock.
This cooktop is manufactured with the frame connected to the bare ground wire. Connect the cooktop cable to the junction box through the UL listed or CSA approved conduit connector.
1.Disconnect power.
2.Remove junction box cover, if present.
3.Connect the flexible cable conduit from the cooktop to the junction box using a UL listed or CSA approved conduit connector.
4.Tighten screws on conduit connector if present.
5.See the “Electrical Connection Options” chart to complete installation for your type of electrical connection.
Electrical Connection Options
If your home has: | And you will be | Go to Section: |
| connecting to: |
|
A fused | ||
| disconnect or | Power Supply |
| circuit breaker |
|
| box |
|
½" |
|
|
(1.3 cm) |
|
|
IMPORTANT: Use the
A |
| ||
B | E | ||
|
|
| |
|
|
| F |
|
|
| G |
|
|
| |
C | H | ||
D | I | ||
A. Cable from home power supply | F. White wires | ||
B. Black wires | G. UL listed wire connector | ||
C. Bare ground wires | H. Red wires | ||
D. | I. UL listed or CSA approved | ||
E. Junction box | conduit connector |
1.Connect the 2 black wires together using the UL listed wire connectors.
2.Connect the 2 red wires together using the UL listed wire connectors.
3.Connect the 2 white wires together using the UL listed wire connectors.
4.Connect the green (or bare) ground wire from the cooktop cable to the green (or bare) ground wire (in the junction box) using the UL listed wire connectors.
5.Install junction box cover.
A fused | ||
| disconnect or | Power Supply |
| circuit breaker |
|
| box |
|
| ½" |
|
| (1.3 cm) |
|