Make Electrical Connection

WARNING

Electrical Shock Hazard

Disconnect power before servicing.

Use 8 gauge copper wire.

Electrically ground cooktop.

Failure to follow these instructions can result in death, fire, or electrical shock.

This cooktop is manufactured with the frame connected to the bare ground wire. Connect the cooktop cable to the junction box through the UL listed or CSA approved conduit connector.

1.Disconnect power.

2.Remove junction box cover, if present.

3.Connect the flexible cable conduit from the cooktop to the junction box using a UL listed or CSA approved conduit connector.

4.Tighten screws on conduit connector if present.

5.See the “Electrical Connection Options” chart to complete installation for your type of electrical connection.

Electrical Connection Options

If your home has:

And you will be

Go to Section:

 

connecting to:

 

4-wire

A fused

4-Wire Cable from

 

disconnect or

Power Supply

 

circuit breaker

 

 

box

 

½"

 

 

(1.3 cm)

 

 

4-Wire Cable from Home Power Supply to 4-Wire Cable from Cooktop

IMPORTANT: Use the 4-wire cable from home power supply in the U.S. where local codes do not allow grounding through neutral, new branch circuit installations (1996 NEC), mobile homes and recreational vehicles, new construction, and in Canada.

A

 

B

E

 

 

 

 

 

 

F

 

 

 

G

 

 

 

C

H

D

I

A. Cable from home power supply

F. White wires

B. Black wires

G. UL listed wire connector

C. Bare ground wires

H. Red wires

D. 4-wire cable from cooktop

I. UL listed or CSA approved

E. Junction box

conduit connector

1.Connect the 2 black wires together using the UL listed wire connectors.

2.Connect the 2 red wires together using the UL listed wire connectors.

3.Connect the 2 white wires together using the UL listed wire connectors.

4.Connect the green (or bare) ground wire from the cooktop cable to the green (or bare) ground wire (in the junction box) using the UL listed wire connectors.

5.Install junction box cover.

3-wire

A fused

3-Wire Cable from

 

disconnect or

Power Supply

 

circuit breaker

 

 

box

 

 

½"

 

 

(1.3 cm)

 

9

Page 9
Image 9
Jenn-Air W10436037B installation instructions Make Electrical Connection, Electrical Connection Options