RELAY 20067

TL- Power Switch

PS- Pressure Switch

SW2- Drain Switch

CR1 + CR2 - Micro Relay Switches

M1 + M2 + M3: Timer Cam Switches

TC- Start Switch

MP - Door Switch

TB - Thermostat

TV - Thermostat

CCB - Booster Contactor Contacts

ELB - Solenoid Coil

1 888 275 4538 - 611

514 737 9701 - 611 FAX 514 737 2792

PD - Soap Pump

BR - Micro Relay coil

BCB - Booster Contactor coil RV - Wash Tank Heater Element RB - Booster Tank Heater Element DP - Drain Pump

MT - Timer Motor

MPL - Wash Pump Motor

LL - Indicator Light - Power

LC - Indicator Light - Wash Cycle

LP - Indicator Light - Temperature Ready CA - Capacitor - wash pump

Function of the 20067 relay

This relay once activated by the start-switch signal is design to hold the current until the first cam of the timer hits the micro switch on the timer. At that moment the signal on the relay is disengaged and the timer takes over the start of the wash cycle.

If this part fails, the start switch must be pressed and held for 15 seconds in order to start the wash cycle.

Relay Location

13

Page 13
Image 13
Jettech Metal Products F18-DP manual CR1 + CR2 Micro Relay Switches, BR Micro Relay coil