John Lewis JLBIOS601 Installation, Electrical Connection, Technical Data, Heating elements rating

Models: JLBIOS601

1 24
Download 24 pages 1018 b
Page 5
Image 5
Installation

Installation

Technical Data

 

Heating elements rating

 

 

Dimensions of recess

 

Fan Oven

2,000

W

 

 

 

 

Height

580 mm

Grill element

1,650

W

 

 

 

Width

560 mm

Convection Fan

25 W

Depth

550 mm

Oven Light

25 W

 

 

Cooling Fan

25 W

Dimensions of the oven cavity

 

Total Rating

2,050

W

Height

335 mm

Supply voltage (50 Hz)

230 V

Width

395 mm

 

 

 

Depth

400 mm

 

 

 

Oven capacity

53 litres

 

 

 

Electrical Connection

Technical Data THIS OVEN MUST BE EARTHED

Electrical Requirements

Any permanent electrical installation must comply with the latest I.E.E. Regulations and local Electricity Board regulations. For your own safety this should be undertaken by a qualified electrician, e.g. your local Electricity Board, or a contractor who is on the roll of the National Inspection Council for Electrical Installation Contracting (NICEIC).

Electrical Connection

The oven is designed to be connected to 230 V (50 Hz) electricity supply.

Before connecting to the mains supply ensure that the mains voltage corresponds to the voltage on the rating plate on the side of the oven door.

The oven has an easily accessible terminal block which is marked as follows:

Letter L

-

Live terminal

Letter N

-

Neutral terminal

It is necessary that you install a double pole switch between the oven and the electricity supply (mains), with a minimum gap of 3 mm between the switch contacts and of a type suitable for the required load in compliance with the current rules.

The switch must not break the yellow and green earth cable at any point.

It is necessary that the yellow/green earth wire is about 2 cm longer than the live and neutral ones.

Important

After installation and connecting, the cable must be placed so that it cannot at any point reach a temperature of more than 60°C above the ambient temperature.

or E

-

Earth terminal

The cable used to connect the oven to the electrical supply must comply to the specifications given below.

Before the oven is connected, check that the main fuse and the domestic installation can support the load; and that the power supply is properly earthed.

The manufacturer disclaims any responsibility should these safety measures not be carried out.

For UK use only

Connection

Min. size

Cable / flex

Fuse

via

Cable/flex

type

 

 

 

 

 

• Cooker

2.5 mm2

PVC/PVC

20 A

Control

 

twin and

 

Circuit

 

earth

 

 

 

 

 

For Europe use

only

 

 

 

 

 

Min. size Cable/flex

 

Cable / flex type

Fuse

 

 

 

 

2.5 mm2

 

H07 RN-F, H05 RN-F,

15 A

 

 

H05 RR-F, H05 VV-F,

 

 

 

H05 V2V2-F (T90),

 

 

 

H05 BB-F

 

 

 

 

 

5

Page 5
Image 5
John Lewis JLBIOS601 Installation, Electrical Connection, Technical Data, Heating elements rating, Electrical Requirements