INSTALLATION MANUAL
R-410A
OUTDOOR
AIR CONDITIONING
MODELS: 16 SEER - CZF / AC6B / AL6B SERIES 2 TO 5 TONS
LISTED
ISO 9001
Certified Quality
Management System
TABLE OF CONTENTS
GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 UNIT INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 EVACUATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 ELECTRICAL CONNECTIONS . . . . . . . . . . . . . . . . . . . . . . . 5
SYSTEM CHARGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 INSTRUCTING THE OWNER . . . . . . . . . . . . . . . . . . . . . . . 11 AC CONTROL BOARD FUNCTIONALITY . . . . . . . . . . . . . 12 WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
LIST OF FIGURES
Typical Installation with Required Clearances . . . . . . . . . . . . 3 Tubing Hanger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Underground Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Heat Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Typical Field Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Communications Harness Connection . . . . . . . . . . . . . . . . . . 6 CFM Selection Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Communicating AC with Communicating
Air Handler or Furnace . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Communicating AC with
or Furnace using Communicating Interface Control . . . . . . . . 7
Thermostat Wiring – Single Stage Air Conditioner
(with AC control) – PSC Air Handler . . . . . . . . . . . . . . . . . . . . 8
Thermostat Wiring – Single Stage Air Conditioner
(with AC control) – VS Air Handler . . . . . . . . . . . . . . . . . . . . . 9
Thermostat Wiring – Single Stage Air Conditioner
(with AC control) – Modulating Furnace . . . . . . . . . . . . . . . . 10 Wiring Diagram (2 - 4 Ton) . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Wiring Diagram (5 Ton) | 17 |
LIST OF TABLES
12 | Status Code Display | 13 | |
TEST Input Functionality | 13 | Operational Fault Codes | 14 |
Operational Mode Display | 13 | Sensor or Switch Fault Codes | 14 |
Status Code Display | 13 | Wiring Related Fault Codes | 14 |
|
|
|
|
SECTION I: GENERAL
The outdoor units are designed to be connected to a matching indoor coil with sweat connect lines. Sweat connect units are factory charged with refrigerant for the highest sales volume evaporator plus 15 feet of field supplied lines.
Matching indoor coils are available with a thermal expansion valve or an orifice liquid feed sized for the most common usage. The orifice size and/or refrigerant charge may need to be changed for some system combinations, elevation differences, or total line lengths. See tabular data sheet provided in unit literature packet for charge requirements. Refer to Application Data covering “General Piping Recommendations and Refrigerant Line Length” (Part Number 247077).
SECTION II: SAFETY
This is a safety alert symbol. When you see this symbol on labels or in manuals, be alert to the potential for personal
injury.
Understand and pay particular attention to the signal words DANGER, WARNING, or CAUTION.
DANGER indicates an imminently hazardous situation, which, if not avoided, will result in death or serious injury.
WARNING indicates a potentially hazardous situation, which, if not avoided, could result in death or serious injury.
CAUTION indicates a potentially hazardous situation, which, if not avoided may result in minor or moderate injury. It is also used to alert against unsafe practices and hazards involving only property dam- age.