13 SEER AC WITH AHP / SHP / AHX / F*FP
TCGD18S41S1(H)
AHP18 17 650 17.5 12.9 13.00 11.00
AHX18 17 - 630 18.0 13.8 14.50 12.00
F4FP024 18 600 17.5 12.9 13.00 11.00
F6FP018 17 - 600 17.8 13.3 14.50 12.00
TCGD24S41S1(H)
AHP30 17 795 24.0 16.8 13.00 11.00
AHX30 17 820 24.0 16.9 14.50 12.00
AHX36 21 815 24.0 16.9 14.50 12.00
F4FP036 21.5 800 24.0 16.7 13.00 11.00
F6FP030 17 850 24.0 16.8 14.00 11.80
F6FP036 21 855 24.0 17.0 14.00 12.00
TCGD30S41S1(H)
AHP30 17 1015 29.0 21.0 13.00 11.00
AHP36 21 1040 29.0 21.0 13.00 11.00
AHX30 17 1025 29.4 22.2 14.00 11.75
AHX36 21 1005 30.0 22.3 14.50 12.00
F4FP040 18 1050 29.0 21.0 13.00 11.00
F6FP030 17 1035 29.2 21.6 13.50 11.40
F6FP036 21 980 29.4 21.4 14.00 12.00
TCGD36S41S1(H)
AHP36 21 1235 35.0 24.8 13.00 11.00
AHP42 21 1255 35.0 24.8 13.00 11.00
AHX36 21 1225 35.2 25.0 13.50 11.50
AHX42 21 1190 35.4 25.2 14.00 11.80
F5FP048 24 1235 35.0 24.8 13.00 11.00
F6FP042 21 1290 35.8 25.8 13.50 11.50
TCGD42S41S1(H)
AHP42 21 1485 41.0 29.2 13.00 11.00
AHX42 21 1395 42.0 29.9 14.50 12.00
F5FP048 24 1455 41.0 29.2 13.00 11.00
F6FP042 21 1455 42.0 30.1 14.00 11.75
F6FP048 24 1380 41.5 29.4 13.50 11.70
TCGD48S41S1(H)
AHP/SHP48 24 1675 48.0 34.4 13.00 11.00
AHP/SHP60 24 1600 48.0 35.0 13.50 11.00
AHX48 24 1660 48.0 35.4 13.50 11.50
F5FP048 24 1600 48.0 34.4 13.00 11.00
F5FP060 24 1600 48.0 34.4 13.00 11.00
F6FP048 24 1625 47.0 34.8 13.00 11.30
TCGD60S41S1
AHP/SHP60 24 1850 57.0 38.5 13.00 11.00
AHX60 24 1905 58.5 40.0 13.50 11.50
F5FP060 24 1900 57.0 38.5 13.00 11.00
F6FP060 24 1710 57.5 39.0 13.50 11.50
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210.
Cooling MBH based on 8°F entering air temperature, 50% RH, and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power
input in watt-hours during the same period.
1.MC coils available with a factory installed hor izontal drain pan. See price pages for specific model number.
COOLING CAPACITY - With Air Handler Coils (Continued)
UNIT
MODEL
AIR HANDLER COIL
MODEL1
COOLING
MODEL W RATED
CFM NET MBH SEER EER
TOTAL SENS.