COOLING PERFORMANCE DATA

AIR CONDITIONER MODEL NO.

TCGD60S41S1

 

 

 

 

 

 

 

 

 

 

 

 

INDOOR COIL MODEL NO.

FC/MC/PC60

 

 

 

 

 

 

 

 

 

 

 

 

 

CONDENSING

IDCFM

 

 

1600

 

 

 

 

1800

 

 

 

 

2000

 

 

ENTERING AIR

ID DB (°F)

80

80

75

80

80

80

80

75

80

80

80

80

75

80

80

TEMPERATURE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ID WB (°F)

57

62

62

67

72

57

62

62

67

72

57

62

62

67

72

 

T.C.

55.8

63.8

62.1

65.2

71.9

60.3

65.7

62.8

66.7

69.8

64.8

67.5

63.5

68.2

67.8

65

S.C.

54.7

51.6

41.4

41.1

34.1

58.4

54.2

43.9

42.6

31.9

62.1

56.8

46.5

44.2

29.6

 

KW

3.0

3.0

3.0

3.1

3.1

3.0

3.0

3.0

3.1

3.1

3.0

3.1

3.0

3.1

3.1

 

T.C.

56.9

61.1

58.9

62.7

69.7

59.2

63.0

59.9

64.3

67.9

61.4

64.9

61.0

65.9

66.0

75

S.C.

53.9

50.4

40.5

40.0

33.5

55.8

53.1

43.1

41.8

31.5

57.7

55.7

45.6

43.6

29.5

 

KW

3.4

3.5

3.5

3.5

3.6

3.4

3.5

3.5

3.5

3.5

3.5

3.5

3.5

3.5

3.5

 

T.C.

58.0

58.4

55.7

60.3

67.6

58.0

60.4

57.1

61.9

65.9

58.1

62.4

58.5

63.6

64.1

85

S.C.

53.2

49.3

39.7

39.0

32.9

53.3

52.0

42.2

41.0

31.2

53.4

54.7

44.8

42.9

29.4

 

KW

3.9

3.9

3.9

3.9

4.0

3.9

3.9

3.9

3.9

4.0

3.9

3.9

3.9

3.9

4.0

 

T.C.

59.1

55.7

52.5

56.9

65.5

56.9

57.8

54.3

57.0

63.9

54.7

59.8

56.0

61.2

62.2

95

S.C.

52.4

48.1

38.8

37.9

32.3

50.7

50.9

41.4

38.8

30.8

49.0

53.6

43.9

42.3

29.4

 

KW

4.3

4.3

4.3

4.4

4.5

4.3

4.3

4.3

4.4

4.4

4.3

4.3

4.3

4.4

4.4

 

T.C.

56.4

52.2

48.8

54.0

60.1

54.0

54.3

50.5

55.7

59.7

51.6

56.3

52.2

57.4

59.4

105

S.C.

49.7

45.9

37.5

36.5

29.7

47.9

48.3

40.0

38.7

29.4

46.2

50.6

42.5

40.9

29.0

 

KW

4.9

4.9

4.9

4.9

5.0

4.9

4.9

4.9

5.0

5.0

4.9

4.9

4.9

5.0

5.0

 

T.C.

53.8

48.8

45.2

50.2

54.8

51.2

50.9

46.8

51.9

55.7

48.7

53.0

48.5

53.6

56.6

115

S.C.

47.1

43.8

36.2

35.0

27.3

45.3

45.7

38.6

37.3

27.9

43.5

47.7

41.1

39.6

28.6

 

KW

5.5

5.4

5.4

5.5

5.6

5.5

5.5

5.4

5.5

5.6

5.4

5.5

5.4

5.5

5.6

 

T.C.

51.2

45.4

41.6

46.5

49.4

48.5

47.5

43.2

48.2

51.6

45.7

49.7

44.8

49.8

53.8

125

S.C.

44.5

41.7

34.9

33.6

24.9

42.6

43.2

37.3

35.9

26.5

40.7

44.7

39.7

38.3

28.2

 

KW

6.1

6.0

5.9

6.1

6.2

6.0

6.0

6.0

6.1

6.2

6.0

6.0

6.0

6.1

6.2

NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.

Multipliers for determining the performance with other indoor sections.

NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.

Air Handlers

Coils

T.C.

S.C.

KW

FC/MC62

1.00

1.00

1.00

HC60

1.00

1.00

1.00

UC60

1.00

1.00

1.00

AHP/SHP60

1.00

1.00

1.00

AHX60

1.00

1.00

0.98

AV/SV*60

1.00

1.01

1.00

MV20D

FC/MC60D

1.00

1.01

1.00

MA20D

FC/MC60D

1.00

1.00

1.00

MV20D

FC/MC62D

1.00

1.01

1.00

MA20D

FC/MC62D

1.00

1.00

1.00

F5FP060

1.00

1.00

1.00

F6FP060

1.00

1.00

0.96

F4FV060

1.00

1.00

0.99

Furnaces

Coils

T.C.

S.C.

KW

T*(8,L)X*C16

FC/PC60C

0.99

0.98

0.99

T*(8,L)X*C20

FC/MC/PC60D

1.00

0.98

1.00

T*9X*C16

FC/PC60C

0.98

0.98

0.98

T*9X*C20

FC/PC60C

0.98

0.98

0.98

T*9X*D20

FC/MC/PC60D

0.99

0.98

0.99

T*9X*C20

FC/MC/PC60D

0.99

0.98

0.99

T*(8,L)X*C20

FC/MC62D

1.00

0.98

1.00

T*(8,L)X*C16

UC60C

0.98

0.97

0.98

T*(8,L)X*C20

UC60D

0.99

1.00

0.99

T*9X*C16

FC/PC60C

0.98

0.97

0.98

T*9X*C20

FC/PC60C

0.98

0.97

0.98

T*9X*D20

UC60D

0.98

0.97

0.98

T*(8,L)X*C20

UC60D

0.99

1.00

0.99

T*9X*C20

UC60D

0.98

0.97

0.98

(T*9C/T*9V)*D20

FC/MC/PC60D

0.97

0.95

0.96

T*(8,L)C*C20

FC/MC62D

0.99

0.97

0.94

(T*9C/T*9V)*C20

FC/MC62D

0.98

0.96

0.97

(T*9C/T*9V)*D20

FC/MC62D

0.99

0.96

0.96

T*(8,L)C*C20

FC/PC60C

0.98

0.96

0.94

(T*9C/T*9V)*C20

FC/PC60C

0.97

0.95

0.96

(T*9C/T*9V)*D20

HC60

0.94

0.93

0.95

T*(8,L)C*C20

UC60C

0.95

0.91

0.93

(T*9C/T*9V)*C20

UC60C

0.94

0.90

0.96

(T*9C/T*9V)*D20

UC60D

0.94

0.90

0.95

Subject to change without notice. Published in U.S.A.

359319-BTG-G-0509

Copyright © 2009 by Johnson Controls, Inc. All rights reserved.

Supersedes: 359319-FTG-F-0309

Johnson Controls Unitary Products

5005 York Drive

Norman, OK 73069

Page 18
Image 18
Johnson Controls TCGD18 THRU 60 warranty AHP/SHP60 AHX60, MV20D FC/MC60D MA20D FC/MC62D

TCGD18 THRU 60 specifications

The Johnson Controls TCGD18 THRU 60 is a sophisticated temperature control and monitoring solution designed for commercial and industrial applications. As energy efficiency and operational reliability become increasingly important, this device stands out for its cutting-edge features, advanced technologies, and robust characteristics.

One of the standout features of the TCGD18 THRU 60 is its precision temperature control. Utilizing advanced algorithms, it ensures accurate readings and adjustments, facilitating optimal conditions in various environments. This capability not only enhances comfort but also enables significant energy savings by reducing unnecessary heating or cooling, making it a formidable choice for businesses aiming to lower their operational costs.

The TCGD18 THRU 60 also supports a wide range of communication protocols, including BACnet and Modbus, ensuring seamless integration with existing building management systems. This interoperability is crucial for modern facilities that rely on interconnected devices to monitor and control their operations efficiently.

Another significant characteristic of this temperature control device is its user-friendly interface. Equipped with a clear display and intuitive controls, the TCGD18 THRU 60 makes it easy for operators to monitor and adjust settings as needed. The ability to customize the control parameters enhances its versatility across different applications, which is particularly beneficial for facilities with unique requirements.

With its robust build quality, the TCGD18 THRU 60 is designed for durability and longevity. It can withstand the rigors of industrial environments while maintaining consistent performance. Moreover, it is engineered to minimize downtime, as it features self-diagnostic capabilities that alert users to potential issues before they escalate.

In terms of energy efficiency, the TCGD18 THRU 60 incorporates innovative technologies that contribute to lower energy consumption. Features such as adaptive learning allow it to analyze usage patterns and make real-time adjustments to maintain desired conditions without unnecessary energy expenditure.

In conclusion, the Johnson Controls TCGD18 THRU 60 is a versatile, efficient, and reliable temperature control solution that integrates seamlessly into modern building systems. Its precision control, wide communication support, user-friendly interface, and robust design make it an ideal choice for a variety of commercial and industrial applications, ultimately delivering improved energy savings and enhanced operational efficiency. As demand for smarter, greener solutions grows, devices like the TCGD18 THRU 60 are paving the way toward more sustainable practices in temperature management.