359319-BTG-G-0509

System Charge for Various Matched Systems

 

 

 

 

 

 

 

 

Outdoor Unit

TCGD18

TCGD24

TCGD30

TCGD36

TCGD42

TCGD48

TCGD60

S41S1(H)

S41S1

S41S1(H)

S41S1(H)

S41S1(H)

S41S1(H)

S41S1

 

Required Orifice or TXV 1,2

0.048/4F1

0.055/4F1

0.061/4F1

0.065/4G1

0.075/4G1

0.073/4H1

0.087/4J1

Factory Charge, lbs-oz

3 - 3

3 - 13

3 - 14

4 - 9

4 - 5

4 - 9

5 - 6

 

 

 

 

 

 

Indoor Coil3,4

 

 

Additional Charge, oz

 

 

AHP18

0

AHP30

4

0

AHP36

2

0

AHP42

0

0

AHP/SHP60

0

0

AHX18

0

AHX30

4

0

AHX36

4

2

0

AHX42

8

2

AHX48

0

AHX60

4

AV*24

TXV + 0

AV*36

4

2

0

AV/SV*48

TXV + 2

0

AV/SV*60

TXV + 2

0

F4FP024

0

F4FP036

0

F4FP040

0

F4FV060

0

0

F5FP048

8

2

4

F5FP060

0

0

F6FP018

0

F6FP030

4

0

F6FP036

4

0

F6FP042

8

2

F6FP048

TXV + 2

0

F6FP060

4

FC/MC/PC/18

0

FC/MC/PC32

4

0

FC/MC/PC35

4

0

FC/MC/PC/36

0

FC/MC/PC37

4

2

0

FC/MC/PC43

4

2

0

0

FC/MC/PC48

8

2

4

FC/MC/PC60

0

0

FC/MC62

4

HC18

0

HC30

0

HC36

4

0

HC42

4

2

0

0

HC60

0

UC18

0

UC36

0

UC48

8

2

4

UC60

0

0

FOOTNOTES:

 

 

 

 

 

 

 

1.For applications requiring a TXV use 1TVM series kit.

2.Approved orifice shipped with outdoor unit.

3.Systems matched with furnace or air handlers not equipped with blower-off delays may require blower Time Delay Kit 2FD06700224.

4.PC coils cannot be used in downflow or horizontal applications. FC coils cannot be used in horizontal applications.

PROCEDURES:

1.Unit factory charge listed on the unit nameplate includes refrigerant for the condenser, the smallest evaporator and 15 feet of interconnecting line tubing.

2.Verify the TXV and additional charge required for specific evaporator coil in the system using the above table.

3.Additional charge for the amount of interconnecting line tubing greater than 15 feet at the rate specified in Physical and Electrical Data Table.

4.For orifice or TXV matches requiring additional charge, the refrigerant needs to be weighed in for specific coil match and lineset length.

5.Permanently mark the unit nameplate with the total system charge. Total System Charge = Base Charge (as shipped) + adder for evaporator + adder for line set.

Models 12-48 require start kits for TXV matches.

Johnson Controls Unitary Products

3

Page 3
Image 3
Johnson Controls TCGD18 THRU 60 warranty System Charge for Various Matched Systems, Footnotes, Procedures

TCGD18 THRU 60 specifications

The Johnson Controls TCGD18 THRU 60 is a sophisticated temperature control and monitoring solution designed for commercial and industrial applications. As energy efficiency and operational reliability become increasingly important, this device stands out for its cutting-edge features, advanced technologies, and robust characteristics.

One of the standout features of the TCGD18 THRU 60 is its precision temperature control. Utilizing advanced algorithms, it ensures accurate readings and adjustments, facilitating optimal conditions in various environments. This capability not only enhances comfort but also enables significant energy savings by reducing unnecessary heating or cooling, making it a formidable choice for businesses aiming to lower their operational costs.

The TCGD18 THRU 60 also supports a wide range of communication protocols, including BACnet and Modbus, ensuring seamless integration with existing building management systems. This interoperability is crucial for modern facilities that rely on interconnected devices to monitor and control their operations efficiently.

Another significant characteristic of this temperature control device is its user-friendly interface. Equipped with a clear display and intuitive controls, the TCGD18 THRU 60 makes it easy for operators to monitor and adjust settings as needed. The ability to customize the control parameters enhances its versatility across different applications, which is particularly beneficial for facilities with unique requirements.

With its robust build quality, the TCGD18 THRU 60 is designed for durability and longevity. It can withstand the rigors of industrial environments while maintaining consistent performance. Moreover, it is engineered to minimize downtime, as it features self-diagnostic capabilities that alert users to potential issues before they escalate.

In terms of energy efficiency, the TCGD18 THRU 60 incorporates innovative technologies that contribute to lower energy consumption. Features such as adaptive learning allow it to analyze usage patterns and make real-time adjustments to maintain desired conditions without unnecessary energy expenditure.

In conclusion, the Johnson Controls TCGD18 THRU 60 is a versatile, efficient, and reliable temperature control solution that integrates seamlessly into modern building systems. Its precision control, wide communication support, user-friendly interface, and robust design make it an ideal choice for a variety of commercial and industrial applications, ultimately delivering improved energy savings and enhanced operational efficiency. As demand for smarter, greener solutions grows, devices like the TCGD18 THRU 60 are paving the way toward more sustainable practices in temperature management.