Desa Servicing The Engine, Technical Service, Troubleshooting, Engines Gasoline, Honda, Remedy

Models: Hwi3000a, Mgh3000ga, Mgh3000a, Mgh4000d, Mgh4000di, Mgh5000e, Mgh5000ei, Mgh5000eie, Mgh6500aie

1 32
Download 32 pages 9.92 Kb
Page 15
Image 15
SERVICING THE ENGINE

OWNER’S MANUAL

SERVICING THE ENGINE

Honda parts and services should be handled by your nearest authorized engine service firm. Check the yellow pages of your tele- phone directory under the listing:

Engines Gasoline, Honda

or visit:

www.honda-engines.com

or call Honda direct:

1-800-426-7701

TECHNICAL

SERVICE

You may have further questions about as- sembling, operating, or maintaining this product. If so, you can visit our Technical Service web site at www.desatech.com or contact our Technical Service Department at 1-800-858-8501 (English Only).You may also write to:

DESA Specialty Products™

ATTN: Technical Service Specialty Products P.O. Box 90004

Bowling Green, KY 42102-9004

When contacting DESA Specialty Prod- ucts™, have ready

Your Name

Your Address

Your Phone Number

Model Number of Product

Serial Number

Date of Purchase (Include copy of receipt for written requests).

TROUBLESHOOTING

Note: For additional help, visit DESA International’s technical service web site at www.desatech.com.

Engines Gasoline, Honda WARNING: Only a qualified electrical service person should service and repair generator. Use only factory approved replacement parts.

Note: See engine owner’s manual for engine troubleshooting.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

 

 

 

 

No voltage when starting generator with no

1.

Defective capacitor

1.

Replace capacitor

electrical load

2.

Winding short circuit or loose

2.

Check resistance of coils (see Electrical

 

 

connections

 

Component Specifications, page 16)

 

3.

Defective rotor diode

3.

Replace both diodes on rotor

 

4.

Loss of residual magnetism

4.

Apply 12-volt battery to capacitor ter-

 

 

 

 

minals for 2-3 seconds

 

 

 

 

 

Voltage is less than normal voltage with no

1.

Engine speed too low

1.

Set engine speed to 3720 RPM (62 Hz)

electrical load

 

 

 

with no load

 

2.

Defective rotor diode

2.

Replace both diodes on rotor

 

3.

Partial short circuit in winding

3.

Check resistance of coils (see Electrical

 

 

 

 

Component Specifications, page 16)

 

4.

Defective capacitor

4.

Replace capacitor

 

 

 

 

 

Voltmeter reading more than 10% high with

1.

Engine speed too high

1.

Set engine speed to 3720 RPM (62 Hz)

no electrical load

 

 

 

with no load

 

 

 

 

 

Voltmeter reading correct with no electrical

1.

Defective rotor diode

1.

Replace both diodes on rotor

load, but more than 10% low when electrical

2.

Electrical load too high

2.

Do not overload generator

load is added

3.

Engine not running properly

3.

Contact an authorized engine service

 

 

 

 

center

www.desatech.com

118683

15

Page 15
Image 15