STOPPING ENGINE

R

PORTABLE GASOLINE GENERATORS

OPERATION

Continued

STOPPING ENGINE

IMPORTANT: The engine speed is preset. The throttle is locked in preset position. Do not adjust throttle.

Follow the steps below to stop engine.

1.Remove all electrical loads from gen- erator (see Disconnecting Electrical Loads). Remove electrical loads one at a time.

2.Let engine run for two or three minutes after removing electrical loads. This lets engine cool slightly.

3.Turn engine switch to the OFF position (see Figure 21).

4.Turn fuel valve lever off. Do this by moving valve lever fully to the left (see Figure 22).

Models HWI3000A,

ENGINE SW

MGH3000GA, MGH3000A,

ON

MGH4000D, MGH4000DI,

OFF

 

MGH5000E, and

 

MGH5000EI

 

 

HONDA

Models MGH5000EIE

 

and MGH6500AIE

ON

 

OFF START

 

ENGINE SW

 

CIRCUIT

 

BREAKER

 

ON/push OFF

MAINTENANCE AND REPAIRS

MAINTENANCE AND REPAIRS WARNING: Only a qualified electrical service person should service and repair the alternator onthisgenerator.Useonlyfactory approved replacement parts.

 CAUTION: Shut off generator before performing maintenance. CAUTION: The engine speed is preset. The throttle is locked in preset position. Do not adjust throttle. Preset position lets engine run at 3600 RPM under load. The engine must maintain 3600 RPM for generator to create correct voltage. Running engine at lower speeds will damage gen- erator and powered items.

STORAGE CAUTION: Shut off generator before performing maintenance.

IMPORTANT: Keep generator level when servicing. Never turn generator upside down or stand it on end to service.

Note:We supply the engine owner’s manual with generator. Refer to that manual for questions concerning engine maintenance and repairs.

Non-engine parts require little maintenance. Keep generator clean. Use a damp cloth to clean outside surfaces. Never use water to clean generator. Water can cause damage to internal parts. Use vacuum to clean air inlet and outlet louvers of alternator.

STORAGE

Manual backgroundWARNING:Removeallfuelfrom fuel tank before storing generator. Store fuel in approved container. Storefuelinawell-ventedareafree of open flames or sparks.

Manual background WARNING: The muffler be- comes very hot during operation. The muffler remains hot for a while after shutdown. Let engine cool before storing.

IMPORTANT: Keepgeneratorlevelwhilein storage. Never store generator upside down or standing on end.

Note:We supply the engine owner’s manual with generator. Refer to that manual for questions concerning engine storage.

Use a fuel additive, such as STA-BIL®or an equivalent, when storing generator with fuel in fuel tank. This will minimize fuel gum deposits from forming in engine.

Cover and store generator in a clean, dry place. Do not expose generator to extreme high or low temperatures during storage.

Figure 21 - Engine Switch In OFF Position

Fuel Valve Lever (Off Position)

Figure 22 - Fuel Valve Lever Off (Model MGH6500AIE Shown)