Johnson Controls Unitary Products 21
FIGURE 27: Horizontal Right Configuration

AIRFLOW

HORIZONTAL- RIGHTINDUCER ROTATEDHORIZONTAL- RIGHTINDUCER AS RECEIVED
Move rain gutter
hose to this position.
Move pressure
switch hose to
this position.
Change condensate
drain connection to
the 90° fitting
provided.
Move condensate
drain hose to
this position.
Move rain gutter
hose to this position
Change condensate drain
connection to the 90°
fitting provided Move condensate
drain hose to this position

AIRFLOW

Move pressure
switch hose to
this position.
When drain hose routing changes are required, be sure to cap all un-used openings.
If rerouting hoses - excess length should be cut off so that no sagging loops will collect
and hold condensate, which will cause the furnace to not operate.