Table 17: Power Cord Specifications

IDP250 Installation Guide

Table 17: Power Cord Specifications

Country

Specifications

United States and Canada

UL-approved and CSA-certified

 

Flexible cord minimum spec: No. 18 (1.5 mm2SVT

 

or SJT, 3-conductor

 

Current capacity of 10A minimum

 

Earth-grounding attachment plug with NEMA 5-15P

 

(10A, 125V) configuration

Table 18 on page 60 list environmental specifications.

Table 18: Environmental Specifications

Specification

Value

Operating temperature

41° to 104° F (5° to 40° C)

Storage temperature

-40° to 158° F (-40° to 70° C)

Relative humidity (operating)

8% to 90% noncondensing

Relative humidity (storage)

5% to 95% noncondensing

Altitude (operating)

10,000 ft (3,048 m)

Altitude (storage)

40,000 ft (12,192 m)

Heat dissipation rates depend on the traffic rate and the number and type of features you have enabled. Table 19 on page 60 provides guidelines.

Table 19: Heat Dissipation Guidelines

Specification

Watts

BTU/hour

Minimum

80

273

Maximum

110

375

60IDP250 Technical Specifications