6Others
RS-232C Communication Examples
This section shows the communication examples of RS-232C.
Operating command
Type | Command | Description | |
|
|
| |
Connection check | PC This unit: 21 89 01 00 00 0A | Checks connection | |
This unit PC: 06 89 01 00 00 0A | |||
|
| ||
|
|
| |
Power (On) | PC This unit: 21 89 01 50 57 31 0A | When power is turned on from standby mode | |
This unit PC: 06 89 01 50 57 0A | |||
|
| ||
|
|
| |
Power (Off) | PC This unit: 21 89 01 50 57 30 0A | When power is turned off (standby mode) | |
This unit PC: 06 89 01 50 57 0A | from | ||
| |||
|
|
| |
Input (COMP.) | PC This unit: 21 89 01 49 50 32 0A | When video input is set to component | |
This unit PC: 06 89 01 49 50 0A | |||
|
| ||
|
|
| |
Remote Control | PC This unit: 21 89 01 52 43 37 33 32 45 0A | When the same operation as pressing the | |
(MENU) | This unit PC: 06 89 01 52 43 0A | [MENU] button on the remote control is made | |
|
|
| |
Gamma table | PC This unit: 21 89 01 47 54 34 0A | When switched to “Custom” | |
(Custom) | This unit PC: 06 89 01 47 54 0A | ||
| |||
|
|
| |
Gamma coefficient | PC This unit: 21 89 01 47 50 30 0A | When set to “1.8” | |
(1.8) | This unit PC: 06 89 01 47 50 0A | ||
| |||
|
|
| |
| PC This unit: 21 89 01 47 52 0A |
| |
Gamma data | This unit PC: 06 89 01 47 52 0A | When the red gamma data is set | |
(R) | PC This unit: 512 bytes of gamma data | ||
| |||
| This unit PC: 06 89 01 47 52 0A |
| |
|
|
| |
Test pattern | PC This unit: 21 89 01 54 53 36 0A | When staircase (gray) is set | |
(Staircase) | This unit PC: 06 89 01 54 53 0A | ||
| |||
|
|
|