Basic operation
SET switch | WHITE BALANCE switch | ||
| WHITE BALANCE |
| |
SET. | MANUAL |
| |
| AUTO | PRESET |
|
|
| 3200K | 5600K |
R | B | R FINE ADJ. B |
WHITE BALANCE switch
WHITE BALANCE
SET. | MANUAL |
| |
| AUTO | PRESET |
|
|
| 3200K | 5600K |
R | B | R FINE ADJ. B |
R/B volume control
3White balance adjustment (preset)3200K/5600K switch
WHITE BALANCE switch
WHITE BALANCE
SET. | MANUAL |
| |
| AUTO | PRESET |
|
|
| 3200K | 5600K |
R | B | R FINE ADJ. B |
ADJ R/ADJ B volume controls
While referring to the monitor, shoot a white subject (such as a wall or sheet of paper) in full screen under the same lighting conditions as those that will exist during the actual shoot.
Set the WHITE BALANCE switch to [AUTO].
Hold the [SET] switch to the right. [AUTO WHITE] will blink in the upper left corner of the monitor screen. When white balance adjustment is complete, this indication changes to [AUTO WHITE OK].
For further fine adjustment, use the [ADJ R]/[ADJ B] volume controls for FINE ADJ.
If the indication in the upper left corner of the monitor screen does not change to [AUTO WHITE OK], white balance has not been completely ad- justed.
Check the following points, then retry auto white balance adjustment.
1.Is the light insufficient? Adjust the lighting.
2.Did you shoot a coloured subject? Shoot a white subject.
Connect a measuring instrument such as a waveform monitor to the video signal output jacks and adjust the white balance while watching the waveform.
First, set the WHITE BALANCE switch to [MANUAL]. Adjust the PB, PR output amplitudes to the minimum with the [R]/[B] volume controls.
Adjust the PR with the [R] volume control and the PB with the [B] volume control.
If a measuring instrument is not available, adjust the picture on the monitor screen until it is white. In this case,
Set the WHITE BALANCE switch to [PRESET]. When a halogen lamp is used as a light source, check the
For further fine adjustment, use the [ADJ R]/[ADJ B] volume controls for FINE ADJ.
22