EN 33
MWB
MWB sets the colour temperature for the subject’s light
source so you can shoot with natural colours that are
unaffected by surroundings, even when there are
multiple subjects with different colour temperatures.

PREPARE WHITE OBJECT

1
Point the camcorder at a white, flat object such as a
sheet of white paper.

SELECT MWB

2
Follow step 1 through 3 on page 32 (“Manual White
Balance Adjustment”), select “MWB”.

MEMORIZE WHITE BALANCE

3
Press the MENU Jog Dial until “MWB” begins
blinking. “MWB” blinks while the white balance is
being stored in memory, then the Menu Screen
reappears when memorization is complete.
CLOSE MENU
4
Press the MENU Jog Dial.
NOTES:
To switch to automatic white balance adjustment, set
the M.W.B. in the Menu Screen to “AUTO”, or turn the
Select Dial to “AUTO LOCK”.
Re-adjust the White Balance when the lighting has
changed, when the camcorder has been turned off and
on again, or when the Select Dial’s position has been
changed.
When adjusted by putting coloured paper in front of
the subject in step 1 of “MWB”, this unit makes its
colour temperature standard for automatic white
balance. So you can enjoy shooting with different
colours. For example, when adjusting with red, blue or
yellow colours, the image becomes the colour which
approximates to green, orange or purple respectively.
AUTO
: FINE
: CLOUD
: HALOGEN
MWB
EXIT
M. W. B.
M.W.B. Menu Screen
Select Dial
MENU Jog Dial
LCD monitor or viewfinder