RS232 (continued)

Following the header, a comma is used to delimit the header from the command. All the commands with their descriptions are listed below. All the text strings are terminated with a carriage return (0x0d or 13). Maximum command string length is 250 characters.

OPERATION COMMANDS (Used for day-to-day operation)

COMMAND

OPTIONS OR RANGE

DESCRIPTION

A#

(0-2) 0=4x3,1=Letterbox, 2=Anamorphic

Input Aspect Ratio – for all sources

 

 

 

B#

(0-170) 128 default

Brightness

 

 

 

C#

(0-155) 110 default

Contrast

D#

(0-13) 8 default

Detail

 

 

 

DVI

 

DVI Input

EXT

 

Pass-through Input

 

 

 

FST

 

Report Current System Status

HELP

 

Displays full list of commands for this unit

 

 

 

K#

(0-220) 128 default

Color

 

 

 

OFF

 

Power OFF

 

 

 

ON

 

Power ON

 

 

 

P#

(0-8) [1-8=User, 0=Factory]

Recall Preset

 

 

 

PM#

(0-1) [0=Normal1=Bypass]

Advanced Color System

 

 

 

PY

 

PassThru Transcoded Input

 

 

 

R

 

RGB input

 

 

 

ST

 

Report Current Status

 

 

 

T#

(0-255) 128 default

Tint

 

 

 

TP#

0=Off

 

 

1=100% Color Bars

 

 

2=Reverse Color Bars

 

 

3=10-step Grayscale

 

 

4=Luma Ramp

 

 

5=Cb Ramp

 

 

6=Cr Ramp

 

 

7=Green

 

 

8=Red

 

 

9=Blue

 

 

10=Convergence

 

 

11=Active Boarder

 

 

12=Multiburst

 

 

13=100% Window

 

 

14=PLUGE Test Pattern Selection

 

 

 

 

TPHELP

 

Display Test Pattern Help

V

 

Video input

X

 

YCrCb input

 

 

 

Y

 

S-Video input

 

 

 

14

Page 14
Image 14