52
Time
During recording
During standby
1 field
5m sec
GND
Timelapse recording
Camera switching signal
(open-collector output)

11-1 Rear Panel’s Input/Output

[CAM SW OUT] camera switching signal output

The CAM SW OUT terminal outputs a camera switching timing signal to the connected sequential switcher. The switching interval
can be set with the <CAMERA SW> on the VTR mode 1 setting screen. The camera switching signal is output at ground level.
Camera
switching
signal output
timing
Terminals Signal levels Remarks
About 2
seconds
Min. 400 ms
Min. 400 ms
Alarm
Record mode
LV: 0 V
Max. 10 mA
LV: 0 V
HV: 5 V ~ 12 V
HV:12 V
(output impedance: 4.7 kohms)
Record mode:
repeat recording ON/auto rewind ON
Tape end Manual
operation
Warning Warning reset
HV: 12 V
(output impedance: 4.7 kohms)
Record mode:
repeat recording OFF/auto rewind OFF
ALARM IN
Alarm signal input
ALARM REC OUT
Alarm recording
mode signal output
TAPE END OUT
Tape end signal
output
WARNING/REC
OUT
Warning signal/Rec
mode signal output
ALARM RST IN
Alarm signal reset
input
Input at ground level
Min. 150 ms LV: 0 V
CLOCK RESET IN
Clock reset input Input at ground level
About 150 ms LV: 0 V
CLOCK RESET
OUT
Clock reset output
Output at ground level
Input at high level
Output at high level
Output at high level
Output at ground level

Other input/output terminal signal levels

11 APPENDIXES
With the <CAMERA
SW> function menu
switch set to "1
FIELD"