20
Alarm/sensor ALARM REC [OFF]
recording mode ON
setting
Turns the alarm recording function on or off.
Alarm recording is enabled only in the Timelapse Record mode.
An index code (VISS signal) is also recorded at the start point of alarm
recording as an alarm cue signal.
OFF :Alarm recording is disabled.
ON :This unit enters the 8H (EP) Record mode, when an alarm signal is input
to the rear panel's [ALARM IN] terminal during timelapse recording.
5-2 Contents of the Function Menu Switches
5 SETTING OF THE FUNCTION MENU SWITCHES
FunctionScreens Items Set values
[ ]: Factory setting
SENSOR REC [OFF]
ON
Selects the recording duration for alarm recording or sensor recording.
5 ..... 180 : Alarm or sensor recording is performed for the time specified (5 sec.
to 180 sec.).
TAPE END: Alarm or sensor recording continues until the tape ends.
MANUAL : Alarm or sensor recording continues for as long as alarm signals
are input.
Set to this position when specifying the alarm recording time with a
switcher.
DURATION 5
15
30
60
120
[180]
TAPE END
MANUAL
Turns the sensor recording function on or off. Sensor recording is enabled in
the Stop mode. An index code (VISS signal) is also recorded at the start point of
sensor recording.
OFF :Sensor recording is disabled.
ON :When an alarm signal is input to the rear panel's [ALARM IN] terminal in
the Stop mode. this unit automatically starts recording in the 8H (EP)
Record mode.
Selects whether or not the alarm buzzer sounds during alarm or sensor
recording.
OFF :The buzzer does not sound.
ON :The buzzer sounds.
TAPE END [STOP]
MODE REW
REPEAT
EJECT
BUZZER [OFF]
ON
Set the operation mode at tape end during recording in the case when alarm or
sensor recording is executed even once.
STOP :Stops at tape end.
REW :Rewinds the tape automatically and stops.
REPEAT : Rewinds the tape automatically to the beginning and restarts
recording.
EJECT :The tape is ejected.
Select the RS-232C data transfer speed from 1200 bps, 2400 bps, 4800 bps or
9600 bps.
RS-232C
parameter
setting BAUD RATE 1200
2400
4800
[9600]
This screen is displayed on the on-screen setting screen only when the (optional) RS-232C board
SA-K97U is installed.