CONNECTION/INSTALLATION

Connections on the back

Power supply

TK-C1480U and TK-C1480E (DC 12 V or 24 V)

 

+

-

 

1

2

DC12V

AC24V

CLASS2 ONLY(U TYPE) ISOLATEDPOWER ONLY (E TYPE)

 

 

TX+ TX- RX+ RX- AUX GND

 

 

A B C D

 

 

Y/C OUT

 

SYNC IN

VIDEO OUT

 

 

SEE INST-

 

POWER

RUCTION

 

MANUAL

Connect the DC 12 V or the AC 24 V power

supply to the DC 12V/AC 24V terminals. To

prevent connection errors or a

cable

disconnection, we recommend the use of lug

plates for the connections.

 

 

The following table shows the connection

distances and connection cables provided

that 2-conductor VVF cables (vinyl-insulated

vinyl sheath cables) are used.

 

 

Maximum extension

100 m

260 m

410 m

500 m

(reference)

 

 

 

 

Conductor

1.0mm

1.6mm

2.0mm

2.6mm

diameter

and more

and more

and more

and more

Control signal cables

These cables should be connected only when it is required to control the camera using the RS-442A or RS-485 signals. The use of 0.65 4-conductor twisted pair cables is recom- mended. With these cables, the maximum ex-

tension distance is 1,200 m.

A

TX+

Connect to the other

B

TX-

side in pairs like this.

C

RX+

Connect to the other

D

RX-

side in pairs like this.

 

 

Genlock connection

With some systems, when the external sync signal is a composite video or black burst sig- nal genlocking by applying an external sync input requires the horizontal phase (H PHASE) and colour phase (SC COARSE) to be adjusted.

MEMO

Genlocking is not possible with a signal containing too much jitter, such as a VCR or videodisc playback signal.

For details, consult a JVC authorized dealer.

MEMO

If thin cables are used (i.e. with a high resistance), a significant voltage drop will occur when the unit is at its maximum power consumption. Either use a thick cable to restrict the voltage drop at the camera side to below 10%, or place the power supply near to the camera. If voltage drop occurs during operation, the performance will be unstable.

Attach the cable conductors so that they do not come into contact with the drop prevention wires.

Do not allow input from both a DC 12 V and AC 24 V power supply at the same time.

When using a DC 12 V power supply, ensure that the polarities of the cable are correct.

The AC 24 V power supply should conform to the following: TK-C1480U Class 2 only

TK-C1480E Isolated power supply only

TK-C1481EG (AC230V)

Y/C OUT

Power cable connect to the commercial AC230V outlet

CAUTION: When you use this camera, the socket-out- let shall be installed near equipment so

SYNC IN

VIDEO OUT

as to disconnect easily.

 

 

 

SEE INST-

 

 

RUCTION

POWER

 

MANUAL

E-16

E-17

Page 9
Image 9
JVC TK-C1480 manual Connections on the back, Memo, TK-C1481EG AC230V, As to disconnect easily