Setting Up the Camera Using RM-P2580 (continued)

 

 

26 EN

 

 

 

 

 

 

 

CAMERA TITLE/ALARM Screen

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Item

 

 

Function/Set Value

 

Initial

 

 

 

 

 

 

 

 

 

Value

 

 

 

 

 

CAM. TITLE EDIT..

 

Use this to specify the title that is always displayed at the bottom left of the screen. Specify

 

^

 

 

 

 

 

 

up to a maximum of 16 characters. ACAMERA TITLE SetupB (A pg. 34)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AREA DISPLAY

 

Use this to perform area setting.

 

 

 

 

 

 

 

 

AAREA DISPLAY Setup (TITLE)B (A pg. 35)

 

OFF

 

 

 

 

 

 

AAREA DISPLAY Setup (DIRECTION)B (A pg. 36)

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF

 

Not displayed.

 

 

 

 

 

 

 

 

 

 

 

 

 

TITLE

 

Equally divides the 360° panning range into 16 areas, and a title of up to 16 characters can

 

 

 

 

 

 

 

 

be specified for each area. The corresponding area title specified will be displayed upon

 

 

 

 

 

 

 

 

panning the camera manually. AAREA DISPLAY Setup (TITLE)B (A pg. 35)

 

^

 

 

 

 

 

 

 

 

 

 

 

DIR

 

Set N (North), which is the direction of the standard axis. When the camera is panned manually,

 

 

 

 

 

 

 

 

the 360° panning range will be equally divided into 8 areas, each indicated by N, NE, E, SE, S,

 

 

 

 

 

 

 

 

SW, W and NW respectively. AAREA DISPLAY Setup (DIRECTION)B (A pg. 36)

 

 

 

 

 

 

 

 

ALARM TITLE SIZE

 

Use this to set the size of the title during an alarm.

 

 

 

 

 

 

 

 

NORMAL: Same size as characters on the menu screen.

 

DOUBLE

 

 

 

 

 

 

DOUBLE: Double the size, both vertically and horizontally, of the characters on the menu screen.

 

 

 

 

 

 

 

ALARM TITLE

 

This is a screen for setting the title during an alarm.

 

^

EDIT..

 

AALARM TITLE SetupB (A pg. 37)

 

 

 

 

 

 

 

 

 

ALARM INPUT..

 

These items are used to perform setting related to the alarm input terminals.

 

 

 

 

 

 

 

 

 

 

 

 

 

MODE

 

For selecting the mode of the camera for which images are to be output when there is an alarm input.

 

 

 

 

 

 

 

 

OFF

: Does not output images even when there is an alarm input.

 

 

 

 

 

 

 

 

HOME

: Output images at the home position during an alarm input.

 

 

 

 

 

 

 

 

POS1-99 : Output images at a selected preset position during an alarm input.

 

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MEMO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Setting the AB&W MODEB (A pg. 27) item to AALARM INB switches the mode to the B&W mode and

 

 

 

 

 

 

 

 

setting cannot be changed.

 

 

 

 

 

 

 

 

 

 

 

 

 

POLARITY

 

For setting the polarity of alarm input signals.

 

 

 

 

 

 

 

 

MAKE

: Input alarm signals when the contact between each alarm input terminal and the

 

 

 

 

 

 

 

 

 

GND terminal changes from open to closed.

 

 

 

 

 

 

 

 

BREAK

: Input alarm signals when the contact between each alarm input terminal and the

 

MAKE

 

 

 

 

 

 

 

GND terminal changes from closed to open.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MEMO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This item will be displayed as "- - -" when the AMODEB item is set to AOFFB and setting is not possible.

 

 

 

 

 

 

 

 

 

 

 

 

 

TIME

 

Use this to set the duration of alarm signal output as well as alarm title display when there is

 

 

 

 

 

 

 

 

an alarm.

 

 

 

 

 

 

 

 

 

[Set values: 5 s, 6 s, 7 s, 8 s, 9 s, 10 s, 15 s, 20 s, 30 s, 60 s]

 

 

 

 

 

 

 

 

8 CAUTION

 

 

 

 

 

 

 

 

For RM-P2580 systems, this setting is disabled. Set using the Alarm Time item of RM-

 

5 s

 

 

 

 

 

 

P2580. (A RM-P2580 AINSTRUCTIONSB)

 

 

 

 

 

 

 

 

MEMO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This item will be displayed as "- - -" when the AMODEB item is set to AOFFB or when the AB&W MODEB

 

 

 

 

 

 

 

 

(A pg. 27) item is set to AALARM INB. In both cases, setting will not be possible.

 

 

 

 

 

 

 

 

 

 

 

 

 

PRIORITY

 

Sets whether or not manual operation is accepted in case an alarm input is recognized

 

 

 

 

 

 

 

 

during manual operation of the camera.

 

 

 

 

 

 

 

 

ALARM

: Manual operation is not accepted when there is an alarm input.

 

 

 

 

 

 

 

 

 

(Priority given to alarm)

 

 

 

 

 

 

 

 

MANUAL : Manual operation is accepted even when there is an alarm input.

 

ALARM

 

 

 

 

 

 

 

(Priority given to manual)

 

 

 

 

 

 

 

 

8 CAUTION

 

 

 

 

 

 

 

 

This item is invalid with a system using the RM-P2580. With this system, the ALARM

 

 

 

 

 

 

 

 

input will permanently override manual operation.

 

 

 

 

 

 

 

 

ALARM OUTPUT..

 

Use this to perform setting related to the alarm output terminal.

 

 

 

 

 

 

 

 

OFF

: Do not output alarm.

 

 

 

 

 

 

 

 

ALARM

: Output alarm signals when there is an alarm input.

 

OFF

 

 

 

 

 

 

B&W

: Output alarm signals when the camera switches to the B&W mode.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PRESET

: Output alarm signals when the camera moves to a preset position.

 

 

 

 

 

 

 

 

AUX 1 to AUX 3 : Output alarm signals when there is an auxiliary input.

 

 

 

 

 

 

 

 

 

 

 

 

Page 26
Image 26
JVC TK-C625 manual 26 EN, Camera TITLE/ALARM Screen

TK-C625 specifications

The JVC TK-C625 is a compact yet highly effective industrial camera that has made a significant impact in various surveillance and monitoring contexts. Developed by JVC, a pioneer in video technology, the TK-C625 stands out for its impressive features, innovative technologies, and reliable performance.

At the heart of the TK-C625 is a high-resolution CCD sensor, which captures images with exceptional clarity and detail. With a resolution of 600 TV lines, this camera is adept at delivering sharp images even in challenging lighting conditions. This capability makes it suitable for a variety of environments, including retail spaces, educational institutions, and parking lots, where detail and accuracy are paramount.

One of the notable features of the TK-C625 is its effective low-light performance. Equipped with a built-in Automatic Gain Control (AGC) feature, the camera can enhance sensitivity in low-light environments, ensuring that quality footage can be captured even in dimly lit areas. This feature is crucial for security applications where monitoring takes place during nighttime hours.

In addition to its impressive imaging capabilities, the TK-C625 offers versatile mounting options. The compact design allows for a range of installation configurations, including wall, ceiling, or even desktop setups. The camera's lightweight build is also a plus, facilitating ease of installation without compromising on stability.

The JVC TK-C625 incorporates advanced signal processing technologies, providing enhanced image quality and reducing noise, which is particularly important in surveillance situations where clarity can mean the difference between identifying a suspect or missing critical details. Its electronic shutter technology allows for quick response to changing light conditions, improving its adaptability to various scenes and preventing overexposure.

Another significant aspect of the TK-C625 is its robust construction. Designed with durability in mind, the camera can withstand the rigors of consistent use in commercial settings, delivering reliable operation over long periods. This resilience is further complemented by its ease of use and maintenance, making it an ideal choice for businesses seeking dependable surveillance solutions.

Overall, the JVC TK-C625 is a high-performance camera that combines advanced features with user-friendly operation. Its high resolution, low-light capabilities, flexible installation, and durable design make it a standout option for surveillance professionals looking for quality and reliability in their monitoring solutions.