Names and Functions of Parts (Front)

H H

A[MENU] Dial (Button)

Scroll up and down this dial to move up and down the cursor (X) for selecting items when the Menu screen is displayed. Press the dial to confirm the selected item.

B[STATUS/MENU] Button

When the normal screen is displayed, press this button to exit the status display set in the Menu (ASPECT MARKER, SAFETY ZONE, CENTER MARK, CAMERA NAME, ZEBRA). Press this button again to display the status.

When the normal screen is displayed, press this button for more than 1 second to display the Menu screen. When the Menu screen is displayed, press this button to exit the Menu screen.

Note

Items where the [ASPECT MARKER], [SAFETY ZONE], [CENTER MARK], [CAMERA NAME], [ZEBRA] display are set to AOFFB in the Menu will not be displayed on the Status screen even when this button is pressed.

C[BRIGHT] Adjustment Control

This adjusts the brightness of the screen. Turn to the right to brighten and turn to the left to darken.

D[CONTRAST] Adjustment Control

This adjusts the contrast of the screen. Turn to the right to increase the contrast and turn to the left to decrease the contrast.

E[PEAKING] Adjustment Control

This adjusts the peaking of the screen. Turn to the right to sharpen the contour and turn to the left to soften.

Caution

When this product is connected to GY-HD250U, the LCD monitor display of the camera can be changed if you turn the PEAKING control on the camera. However, the monitor display at VF-HP840U cannot be changed. PEAKING for VF- HP840U must be operated on VF-HP840U.

A

MENUB

STATUS

BRIGHT C

4

 

D

6

 

CONTRAST

5

 

6

E

PEAKING

5

 

4

 

 

1:1

 

F

FOCUS

 

G

ASSIST

 

H

When connected to GY-HD250U and [VF SIGNAL] setting at the camera is set to ARGBB, [PEAKING] adjustment at the camera is forced to off.

The above feature may not function depending on the

version of the camera’s software. For details, please consult JVC’s authorized dealers.

F[1 : 1] Button

Press this button to display the input video signals 1: 1 without resizing. During this display, the [ASPECT MARKER], [SAFETY ZONE], [CENTER MARK] display will be temporarily AOFFB.

G[FOCUS ASSIST] Button

Press this button to display the focused area in color. Accurate focusing can be done. (PEAKING cannot be adjusted.)

Note

The color and level of the focused area can be changed at the Menu screen. (A Page 14)

When connected to GY-HD250U and [VF SIGNAL] is set to ARGBB at the camera LCD/VF MENU screen, set FOCUS ASSIST at the camera to AOFFB. Settings at VF will be invalid.

When connected to GY-HD250U and the FOCUS ASSIST setting on the camera is ON, pressing the [FOCUS ASSIST] button of this product will display APLEASE CHECK CAMERA SETTINGB.

When connected to GY-HD250U, the product will not operate under the following conditions.

During BARS ON, SKIN COLOR ADJUST or SKIN AREA SW ON

When connected to GY-HD250U, as the character being output from the camera is recognized as focus area, set [ANALOG OUTPUT CHAR.] at the camera to AOFFB.

HTALLY Lamp

This displays the monitor status of the input screen in red or green. When Tally PGM (Program) signals are input, the lamp lights up in red. When Tally PVM (Preview) signals are input, the lamp lights up in green.

When CALL signals are input, the lamp blinks in red.

7