HTTPS and SNMP Function

Update Procedure

The camera's default settings do not support using the HTTPS and SNMP functions. To use the HTTPS and SNMP functions, use the firmware update function via the Maintenance Page, and update to the firmware version designated below. (A Page 79)

Acquire firmware for updating via the site below.

http://www3.jvckenwood.com/english/pro/vnetworks/index.html

The file names of the firmware files used for updating are as follows.

h137u_v2.00.214forSupport.img

 

 

 

 

 

 

 

 

 

Model name

 

 

 

 

 

Version number

 

 

or

h137u_v2.00.214woActiveX.img

 

 

 

 

 

 

 

 

 

Model name

 

 

 

 

 

Version number

 

 

To use the HTTPS and SNMP functions, update using the firmware with the following file name characteristics.

h***_v*.**..www.woActiveX.img

Note:

ActiveX for the Built-in Viewer is not included; with the camera at its factory default settings, install the Built-in Viewer's ActiveX to your computer via Internet Explorer while set to the factory default settings, and update the camera's firmware.

To revert to the original firmware for which the HTTPS and SNMP functions cannot be used, return the camera settings to factory defaults, and update using the firmware with the following file name characteristics.

h***_v*.**.***forSupport.img

You can install ActiveX to your computer by accessing the Built-in Viewer URL via Internet Explorer.