Mounting this Camera

Note

Special attention is required when installing the camera to the wall or ceiling. You should not carry out installation work yourself. Ask a professional to do the job, because injuries and accidents may occur if the camera falls.

To prevent this camera from falling, connect it to a strong section (a ceiling slab or channel) using a fall prevention wire.

When you attach the camera body to the ceiling, be sure to wear safety goggles to protect your eyes from falling objects.

Mounting the lens (VN-H57U/VN-H37U)

Note

• Use a Megapixel lens only.

1Check the lens mount before mounting the lens.

The VN-H37U has the CS mount.

The lens mount size (a) must be as shown in the table below.

 

Lens

Flange focus (b)

 

 

Dimension (a)

 

CS mount lens

12.5 mm

 

 

5.5 mm or less

• Never use a lens whose dimension

 

 

(a)

 

Flange focus

 

(a) is more than the specified value.

 

 

 

 

Otherwise, the lens may not be

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

mounted correctly, or internal parts

 

 

 

 

 

 

 

 

 

of the camera may be damaged.

 

 

 

 

 

(b)

 

 

Also, the camera may fail.

 

 

 

 

 

 

 

 

2Mount the lens securely by rotating it clockwise (CW).

3When using a DC iris lens, connect the lens cable to the IRIS terminal at the side of this camera.

Memo

You cannot use a video iris lens.

If the lens cable plug does not match, use a 4-pin plug. [4-pin plug part number: SCV2859-001]

The 4-pin plug is available from the dealer or a JVC Service Center.

Mounting this camera onto a fixer, pan/tilt unit and similar object

When you mount the camera onto a fixer, pan/tilt unit or similar object, use the tripod screw hole (1/4-20UNC) of the camera-mounting bracket.

When you mount the camera on a high place, fix the fall-prevention wire to the wire attachment screw on the camera rear panel.

 

Camera-

Camera-mounting

mounting

bracket

bracket

1/4-20UNC

 

Camera-mounting

5 mm to

screws (x2: M2.6 x

7 mm

8 mm)

 

Screw hole for the camera-

Rotation-

mounting (1/4-20UNC)

preventive

 

hole

Note

Tighten setscrews securely.

Use the screws to mount the camera so that the screws protrude between 5 and 7 mm from the mounting surface. Do not use screws that exceed the specified length as it may damage the internal parts.

VN-H57U

[STATUS] indicator

Iris terminal

Camera-mounting bracket

VN-H37U

[STATUS] indicator

Iris terminal

Camera-mounting bracket

Mounting the fall prevention wire

 

Fall prevention wire

 

(Prepared by customer)

6 mm

Attachment screw for

 

fall prevention wire

2 mm or less

(M3 x 6 mm)

 

Note

Take note of the length, strength and pull of the fall prevention wire. For the fall prevention wire use the insulation material. Make the wire length as short as possible.

The wire must be sufficiently strong to hold the weight of the camera and the total weight of the lens and fixer. (Also, make sure that the wire ends are terminated carefully)

Use the screws mounted on the camera rear panel to hold the fall prevention wire.

Mount the fall prevention wire using an attachment screw for the fall prevention wire.

Use the screws (M3 x 6 mm) mounted on the rear panel of the camera to hold the fall prevention wire. Do not use a screw that is longer than 6 mm as doing so may damage the inside of the camera.

Attach the camera-mounting bracket to the top of this camera

Memo

The bracket is attached to the bottom of this camera before being shipped from the factory. Remove two screws for the camera-mounting bracket and attach the bracket to the top of the camera if required.

Two (M2.6 x 8 mm) screws to secure the camera-mounting bracket

[STATUS]

indicator Camera-mounting bracket

Camera-mounting bracket

Two (M2.6 x 8 mm) screws to secure the camera-mounting bracket

Note

Use setscrews with a length of 8 mm or less to secure the camera- mounting bracket. Do not use screws that exceed the specified length as it may damage the internal parts.

Two (M2.6 x 8 mm) screws to secure the camera-mounting bracket

VN-H137U

[STATUS] indicator

Camera-mounting bracket

Camera-mounting bracket

Screw hole for the camera- mounting (1/4-20UNC)

Attaching cables

Power Connection

When using the PoE cable (Common)

Power is supplied via the LAN cable. Connect the PoE power sourcing equipment.

When power is supplied, the [STATUS] indicator lights up orange on the side of this camera and lights up green after booting.

Memo

You can also turn the [STATUS] indication Off when the camera is operating. For details about the settings, see “Instructions (Setting)” on the supplied CD-ROM.

A Category-5 or higher grade cable is recommended for 100BASE-TX communication.

Be sure to properly ground the PoE power sourcing equipment before use.

PoE power sourcing

PoE power sourcing

equipment

equipment

VN-H57U VN-H37U/VN-H137U
When connecting the AC 24 V power cable (VN-H57U)

When power is supplied, the [STATUS] indicator lights up on the camera side panel.

Note

Always use an AC 24 V power supply that is insulated from the primary power circuit. An autotransformer or similar single-winding transformer may fail or damage the camera.

If you use both the AC 24 V power cable and the PoE-based LAN cable simultaneously, the camera may fail. Always supply power using either method.

VN-H57U

 

 

Speaker with integrated amp

[MONITOR] terminal

Plug-in power condenser

 

[AUDIO IN/

microphone

 

OUT] terminal

 

Test monitor

 

 

 

 

75 Ω

 

* For field angle

 

termination

adjustment

 

 

 

[MONITOR] selection switch

 

 

 

NTSC

 

 

 

PAL

 

 

 

[RESET] button

 

 

 

[FOCUS ASSIST] button

To AC 24 V

Cable stopper

Alarm cable

 

 

power supply

 

 

 

VN-H37U/VN-H137U

 

 

[MONITOR] terminal

 

Test monitor

 

* For field angle

 

 

 

 

 

 

adjustment

75 Ω termination

[MONITOR] selection switch

NTSC

PAL

[RESET] button

[FOCUS ASSIST] button

Memo

The camera has the 16:9 aspect ratio. If the test monitor for checking the image has the 4:3 aspect ratio, the camera image is converted and displayed in the 4:3 ratio.

Connecting the monitor signal output terminal to the coaxial cable (Common)

Connect a test monitor to the [MONITOR] terminal.

Use this terminal to adjust the field angle during camera setup and to adjust the focus in Focus Assist mode. Connect an RCA video cable from this MONITOR terminal to the video monitor. When using a PAL system monitor, set the [MONITOR] switch to the "PAL" position. Then, press the RESET button to restart the camera.

Note

If you extend the cable, more signals attenuate, the video resolution drops, and video noise increases. A cable with lower attenuation is recommended for when the camera is attached.

If you keep pressing the [RESET] button for more than 5s, the camera enters the Service mode. Do not press this button for more than 5s.

Connecting the Audio cable (VN-H57U)

Connect the stereo mini jack cable to the [AUDIO IN/OUT] terminal (Φ3.5 mm).

For details about the audio cable, refer to [Audio cable connection] (page 4).

Alarm I/O Terminal Connection (VN-H57U)

Note

An ambient noise source may cause a malfunction of the camera even if the cable length is 50 meters or less. In that case, keep the noise source away from the camera system.

The cable stopper may drop from the Alarm terminal. Securely connect the cables.

Continued overleaf 2