Side / Rear
JK
MONITOR OUT | PAL OFF NTSC | RESET |
STATUS
IRIS
M L
J[MONITOR OUT] Monitor Output Selection Switch
Use this switch to select the availability of output from the N [MONITOR OUT] terminal as well as the signal system.
NTSC : Outputs NTSC signals.
OFF | : No output. Select this value when |
| distributing images to the network. |
PAL | : Outputs PAL signals. |
[Default setting: OFF]
Caution:
●Images are not distributed to the network when ANTSCB or APALB is selected.
●When the switch is changed, press the K Reset button to reboot the unit.
K [RESET] Reset Button
This is a button for rebooting the camera. Press this button and release within 5 seconds to reboot the camera.
It takes about one minute for the camera to reboot. During startup, the [RESET] button is disabled.
Note:
Pressing the [RESET] button for 5 seconds or longer switches the camera to the service verification mode. Do not press the button for 5 seconds or longer.
L [IRIS] Iris Terminal
Use this terminal to connect the DC iris lens. (Connection with the video iris lens is not possible.)
M [STATUS] Status Indicator
This status of this product is indicated in green or orange color.
Starting up: Lights up in orange
Startup complete: Lights up in green
Error: Blinking (orange or green)
QP
1 | 2 | G 2 | 1 2 | 1 | |
| AC24V | INPUT |
| OUTPUT | |
CLASS 2 ONLY FOR USA OLATEDSI POWER ONLY FOREUROPE AND OTHER | ALARM | R | |||
| |||||
OUT | PoE |
|
| ||
| MONITOR |
|
|
| |
|
|
|
| ||
SEE INSTRUCTION MANUAL |
|
| |||
CAUTION: NEVER USE PoE AND AC 24V AT THE SAME TIME |
| ||||
DO NOT CONNECT TO THE TELEPHONE NETWORK |
| PUSH |
N O
Note:
You can adjust the [LED State] settings via the network to turn off the indicator after startup is complete. (A Page 65)
N [MONITOR OUT] Monitor Video Signal Output Terminal (RCA)
This is an output terminal for composite video signals (1 V
This terminal is used for adjusting the camera angle during installation. (A Page 16)
Note:
●Use the J [MONITOR OUT] switch to select the availability of output as well as the signal
system. When the switch is changed, press the K Reset button to reboot the unit.
●When using the [MONITOR OUT] output, set the privacy mask to AOffB. (A Page 50)
O
Use this terminal to connect to the network via a LAN cable.
This product supports PoE (IEEE802.3af class 2) and therefore can be used without a power cable. (A Page 14)(A Page 16)
P [ALARM INPUT/OUTPUT] Alarm Input/ Output Terminals
Use these terminals to connect to an external alarm device.
Q [AC24V] Power Input Terminal
Use this terminal to connect to an AC 24 V, 50/60 Hz power supply.
R Fall Prevention Wire Mounting Screw (M3 x 6 mm)
Use this screw to mount the fall prevention wire. (A Page 18)