Connecting to the AC 24 V power supply
Connect this product to the AC 24 V power supply when the PoE is not used.
Caution:
●Make sure to select only one mode of electrical supply. Connecting the power cord and the LAN cable for the PoE at the same time may result in failure or malfunction of the camera.
●The unit is to be powered by an AC 24 V power supply.
The AC 24 V power supply should conform to the following: Class 2 only (For USA), Isolated power supply only (For Europe and others).
To Power
Supply
1 | 2 | G 2 1 2 1 |
| AC24V | INPUT | OUTPUT |
CLASS2 ONLY FOR USA ISOLATEDPOWER ONLY FOREUROPE AND OTHER | ALARM |
| |
|
| ||
OUT | PoE |
| |
| MONITOR |
|
|
|
|
| |
SEE INSTRUCTION MANUAL |
| ||
CAUTION: NEVER USE PoE AND AC 24V AT THE SAME TIME |
| ||
DO NOT CONNECT TO THE TELEPHONE NETWORK | PUSH |
MONITOR OUT | PAL OFF NTSC | RESET |
STATUS
IRIS
Status Indicator
Power cord
●To prevent misconnection and detachment of cords, use a lug plate to connect the cord to the terminal.
●When a
Maximum | 150 | 400 | 630 |
Extension (m) |
|
|
|
|
|
|
|
Conductor | R1.0 | R1.6 | R2.0 |
Diameter (mm) | and | and | and |
| above | above | above |
|
|
|
|
Warning
The rated power of this product is AC 24 V, 50 Hz/60 Hz. Make sure to use it with the correct voltage.
Use an AC 24 V supply that is isolated from the primary power supply.
Supplying a power beyond the rated value may result in failures, smoke or fire. When the camera breaks down, turn off the power and contact our service center immediately. When a power beyond the rated value is supplied, the internal components may be damaged even if no abnormality is found on the appearance and operation of the camera. Please contact our service center immediately for servicing (charged separately).
Note:
●After DHCP timeout, all IP addresses of
●In a system where multiple units of
●When overlapping of the IP address occurs, check to ensure that there is only one
15