Alarm Input/Output Terminal Connection

Connect the alarm input/output terminals with external devices, such as a sensor or buzzer. Plug/Unplug the cable while pressing the button as shown in the diagram below.

Cable to use

Shielded cable

Length of 50 m or shorter

1

2

G 2 1 2 1

 

AC24V

INPUT

OUTPUT

CLASS2 ONLY FOR USA ISOLATEDPOWER ONLY FOREUROPE AND OTHER

ALARM

 

 

 

OUT

PoE

 

 

MONITOR

 

 

 

 

10BASE-T/

 

SEE INSTRUCTION MANUAL

100BASE-TX

 

CAUTION: NEVER USE PoE AND AC 24V AT THE SAME TIME

 

DO NOT CONNECT TO THE TELEPHONE NETWORK

PUSH

Push

Caution:

Noises from an external source may cause the camera to malfunction even when the cable used is within 50 m. In this case, move the cable away from the noise source.

Alarm Input Terminal

Connect this terminal to sensor devices, such as an infrared sensor, door sensor, metal sensor or manual switch.

Input requirements

No-voltage relay NPN open collector input

Polarity of input detection can be selected using a software

Make/Break (500 ms and above)

Circuit current at low level: 1 mA

Applied voltage at high level: 3.3 V

VN-V25U

 

Sensor Example

DC3.3 V INPUT 1 or

 

(1)

 

VCC

2 Terminal

 

R

OUT

R

 

 

 

3.3 V 1 mA

 

G Terminal

GND

 

(Alarm Input Equivalent Circuit)

 

Sensor Example

 

 

 

 

(2)

 

 

Relay Switch, etc.

OUT

GND

Alarm Output Terminal

Connect this terminal to annunciating devices, such as annunciators, indicators, lights, or buzzers.

Output requirements

Equivalent to NPN open collector output (Set the output logic using the Internet Explorer)

Allowable applied voltage: DC12 V and below

Allowable inflow current: 50 mA

Momentary (100 ms - 5000 ms) output (Set time using the Internet Explorer (A Page 46))

 

 

 

 

Annunciating

 

 

 

 

 

Device Example

 

VN-V25U

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTPUT 1

 

 

 

 

 

 

 

DC 12 V

or 2 Terminal

IN

R

 

 

 

 

 

 

 

 

 

 

 

G Terminal GND

(Alarm Output Equivalent Circuit)

Caution:

Connect the G terminal of this camera to the GND terminal of the annunciating device or alarm input sensor.

17