CONDENSING UNIT
WARNING: DISCONNECT ELECTRICAL POWER SUPPLY BEFORE CLEANING ANY PARTS ON THE UNIT.
The condensing unit coil and filter must be cleaned regularly on
The condensing unit is located behind the louvered panel in the compressor compartment. Remove louvered panel by pulling on the bottom then lifting up and out. Remove rear access panel located in the back of unit. A phillips head screwdriver is required to remove rear access panel. Carefully clean dirt and lint from the condenser coil using a vacuum cleaner or soft brush; do not use a wire brush.
The filter is located behind the louvered panel, below the condensing unit in the compressor compartment. Remove filter by carefully sliding out of the tracks. Carefully clean with vacuum or rinse with hot water exercising care not to bend or damage filter frame. Replace filter by carefully sliding it into the tracks. Replace louvered panel by installing top of panel into track and pushing in the bottom so that the locking clips fit inside the opening. Replace rear access panel. Reconnect electrical supply.
Replacement filters are available through Kairak Parts and Service Department at
EVAPORATOR COILS
WARNING: DISCONNECT ELECTRICAL POWER SUPPLY BEFORE CLEANING ANY PARTS ON THE UNIT.
Evaporator coils should be cleaned every six (6) months for optimal performance.
The evaporator coils are located in the storage cabinet behind the coil can cover. With a phillips head screwdriver, remove four screws and take off cover. Clean evaporator coils with a vacuum cleaner or soft brush, do not use a wire brush. Replace coil can cover. Reconnect electrical supply.