PRESTART CHECKS

KAIRAK

Page 6

PRESTART CHECKS

DEFROST TIME CLOCK SETTINGS

All models have a defrost time clock that is set to defrost 3 times a day for a 15 minute time period. The defrost settings are factory set at 12:00 a.m. to 1:00 a.m., 2:00 a.m. to 2:30 a.m. and 5:00 a.m. to 6:00 a.m. To change this setting, set the pins to desired off times. Each pin represents 15 minutes. Pins pulled out away from center of time clock represent refrigeration off. Pins pushed toward center indicate refrigeration on. Make sure time clock is set to the correct time of day.

To set the time of day, rotate the disc in the direction of the arrows (clockwise rotation) to align the hands to the correct time of day. (See Fig. 4)

ON cycle

Pins in

Timer shown with clock set at 8 a.m.

OFF cycle

Pins out

OFF cycle

Pins out

Fig. 4

- 6 -