If you encounter any additional difficul- Call: 1-800-465-4980for help or visit
ties not listed, please callour website: www.karcher.ca
1-800-537-4129for help or visit our Kärcher Customer Support Mexico website: www.karcher-usa.com/home
Call: 01-800-024-13-13for help or visit
our website: www.karcher.com.mx
14 English
Kärcher Customer Service CDN
Kärcher Customer Support USA

Symptom

Cause

Solution

No detergent.

Detergent suction tube not

Check connection.

 

properly connected to the ma-

 

 

chine.

 

 

Detergent is too thick.

Dilute detergent, for best re-

 

 

 

 

sults use Kärcher detergent.

 

Filter on detergent suction

Run warm water through filter

 

tube is clogged.

to remove debris.

 

Damaged or clogged deter-

Remove obstruction or repla-

 

gent suction tube.

ce detergent suction tube.

 

Spray wand is in high pressu-

Turn spray wand tip to low

 

re position.

pressure position.

 

Discharge nozzle is obstruc-

Blow out or remove debris

 

ted.

with fine needle.

Garden hose con-

Loose fittings.

Tighten fittings.

nection leaks.

Missing/worn rubber washer.

Insert new washer.

Spray wand leaks.

Spray wand not properly atta-

Insert the spray wand into the

 

ched.

trigger gun. Carefully press in

 

 

 

 

against the spring tension

 

 

 

 

and twist into the lokked posi-

 

 

 

 

tion.

 

Broken o-ring or plastic insert.

Call Customer Support

Pump is noisy.

Pump is sucking air.

Check that hoses and fittings

 

 

 

 

are air tight. Turn off machine

 

 

 

 

and purge pump by squee-

 

 

 

 

zing trigger gun until a steady

 

 

 

 

flow of water emerges throu-

 

 

 

 

gh the nozzle.

Water leaks from

Loose fittings.

Check that all fittings are

pump (up to 10 drops

 

 

 

tight.

per minute is permis-

Water seals are damaged or

Call Customer Support

sible).

worn.

 

Oil Drip.

Oil seals are damaged or

Call Customer Support

 

worn.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 14
Image 14
Karcher K 2.55 manual Symptom Cause Solution