Figure 2-20. Burner Assembly

Gas

Valve

Main•

 

Pressure•

Main•

Tap

Orifices

 

Manifold

 

Assembly

Figure 2-21. Gas Valve

Adjustment Screw (5 mm)

Adjustment Screw

for minimum pressure

(8 mm) for

setting

maximum

 

pressure

 

setting

F.Adjusting the Minimum Pressure Setting

1.Disconnect pressure feedback connection (if appcable).

2.Connect a suitable pressure gauge to pipe line or to outlet pressure tap of gas control concerned, to measure burner pressure (measuring point must be as near to burner as possible).

3.Disconnect electrical connection of the Moduplus®.

4.Energize operator, set control in operation and wait until an outlet pressure is recorded on pressure gauge.

5.If minimum rate pressure needs adjustment, use an 8 mm wrench to turn adjustment screw for minimum pressure setting (clockwise to increase or counter-clockwise to decrease pressure), until the desired minimum outlet pressure is obtained.

6.Check if main burner lights easily and reliable at minimum pressure.

7.Reconnect pressure feedback connection (if appcable).

8.Close pressure tap screw.

G. Checkout

After any adjustment, set appliance in operation and observe through a component cycle to ensure that burner system components function correctly.

H.Maintenance

It is recommended to check yearly the minimum and the maximum setting and readjust them if necessary.

15

Page 19
Image 19
Karcher PS640G installation manual Adjusting the Minimum Pressure Setting, Checkout, Maintenance