![Recall no. (0...9)](/images/new-backgrounds/15232/1523241x1.webp)
The respective FreqRange (frequency range) can be selected using numbers 0…9.
SwG Level 60.0 dBµV
Recall no. (0...9)
Noise generator
Signal generator
Sweep generator
Channel sweep generator System
SwG FreqRange nr: 0
SwG FreqRange 0 Start 4.00 MHz
SwG FreqRange 0 Stop 10.00 MHz
SwG FreqRange 0 Step 2.00 MHz
SwG FreqRange nr: 1
SwG FreqRange 1 Start 15.00 MHz
SwG FreqRange 1 Stop 30.00 MHz
SwG FreqRange 1 Step 5.00 MHz
SwG FreqRange nr:2
SwG FreqRange 2 Start 40.00 MHz
SwG FreqRange 2 Stop 60.00 MHz
SwG FreqRange 2 Step 20.00 MHz
SwG FreqRange nr:9
SwG FreqRange 9 Start 500.00 MHz
SwG FreqRange 9 Stop 900.00 MHz
SwG FreqRange 9 Step 50.00 MHz
SwG StepTime 150 ms
The functions "Store no. (0…9)" and "Recall no. (0…9)" can be used to store ten full sets of unit settings and call them back up.
Clear clears the screen of MSK33
SwG Tracking no
SwG SelRange 0129............. run
SwG ControlData
Clear |
|
| no run | ||
|
|
| |||
| SwG Store |
| |||
| nr: 9 | (0...9) |
| ||
|
|
|
|
|
|
Prt prints out at MSK33
SwG ControlData Prt 123 no run
Fkt A sets UScart at MSK33
SwG ControlData Fkt A 0 (1) no run
(Switchover Rec 0/1)
Fkt B CVBS input at MSK33
SwG ControlData
Fkt B 0 (1) no
(ext. CVBS picture presentation)
21