Kathrein MVG 10 manual Sweep generator, Recall no

Models: MVG 10

1 28
Download 28 pages 8.45 Kb
Page 21
Image 21
Recall no. (0...9)

The respective FreqRange (frequency range) can be selected using numbers 0…9.

SwG Level 60.0 dBµV

Recall no. (0...9)

Noise generator

Signal generator

Sweep generator

Channel sweep generator System

SwG FreqRange nr: 0

SwG FreqRange 0 Start 4.00 MHz

SwG FreqRange 0 Stop 10.00 MHz

SwG FreqRange 0 Step 2.00 MHz

SwG FreqRange nr: 1

SwG FreqRange 1 Start 15.00 MHz

SwG FreqRange 1 Stop 30.00 MHz

SwG FreqRange 1 Step 5.00 MHz

SwG FreqRange nr:2

SwG FreqRange 2 Start 40.00 MHz

SwG FreqRange 2 Stop 60.00 MHz

SwG FreqRange 2 Step 20.00 MHz

SwG FreqRange nr:9

SwG FreqRange 9 Start 500.00 MHz

SwG FreqRange 9 Stop 900.00 MHz

SwG FreqRange 9 Step 50.00 MHz

SwG StepTime 150 ms

The functions "Store no. (0…9)" and "Recall no. (0…9)" can be used to store ten full sets of unit settings and call them back up.

Clear clears the screen of MSK33

SwG Tracking no

SwG SelRange 0129............. run

SwG ControlData

Clear

 

 

no run

 

 

 

 

SwG Store

 

 

nr: 9

(0...9)

 

 

 

 

 

 

 

Prt prints out at MSK33

SwG ControlData Prt 123 no run

Fkt A sets UScart at MSK33

SwG ControlData Fkt A 0 (1) no run

(Switchover Rec 0/1)

Fkt B CVBS input at MSK33

SwG ControlData

Fkt B 0 (1) no

(ext. CVBS picture presentation)

21