VGO |
|
|
VGF |
| DATA |
Technical Data |
|
|
Type | VGO | Notes |
VOS 952-1G/953-1G DESCRIPTION
Order no. |
| 24410101 |
|
| 24410100 |
|
|
|
|
|
|
|
|
|
| Locally fed | Remotely fed |
| ||
|
|
|
|
|
|
|
FORWARD PATH |
|
|
|
|
|
|
|
|
|
|
|
|
|
Frequency range | MHz |
|
| |||
|
|
|
|
|
|
|
Gain | dB | 40 |
|
|
| |
|
|
|
|
|
|
|
Gain setting range, interstage ³) | dB |
|
|
| ||
|
|
|
|
|
|
|
Amplitude response | dB | ±0.5 |
|
| ||
|
|
|
|
|
|
|
Amplitude response (additional, | dB |
|
| at 25 °C | ||
|
|
|
|
|
|
|
Attenuation setting range, on input ³) | dB |
|
|
| ||
dB |
|
| ||||
Return loss, as of 40 MHz | dB |
|
| |||
|
|
|
|
|
|
|
Noise figure | dB | 4 |
|
| at 40 dB gain | |
|
|
|
|
|
|
|
Max. operational level: CENELEC raster ¹) | dBµV | 116/118 |
| CTB: 60 dB/CSO: 60 dB | ||
|
|
|
|
|
|
|
Hum modulation ratio | dB | - |
|
| 60/70 | AT 7 A, |
|
|
|
|
|
|
|
RETURN PATH |
|
|
|
|
|
|
|
|
|
|
|
|
|
Frequency range | MHz |
|
|
| ||
|
|
|
|
|
| |
Gain (input stage bridged), active operation | dB | 30 (21) |
|
|
| |
|
|
|
|
|
| |
Gain, passive operation | dB |
|
|
| ||
|
|
|
|
|
| |
Amplitude response | dB | 0.5 |
|
|
| |
|
|
|
|
|
| |
Attenuation setting range, at input or interstage ³) | dB | 0/4/8 or |
|
| ||
|
|
|
|
|
| |
dB | 0/3/6 |
|
|
| ||
|
|
|
|
|
| |
Ingress Control Switch (ICS) | dB | 8/> 40 |
|
| ||
|
|
|
|
|
| |
Max. output level at 30 and 21 dB gain | dBµV | 107/116 |
| 60 dB IMod2/IMod3 (EN | ||
|
|
|
|
|
| |
Max. output level | dBµV | 120 |
|
| According to KDG 1 TS 140 (full system load) | |
|
|
|
|
|
| |
Input level density | dBµV/Hz |
|
| CINR at 50 dB (EN | ||
|
|
|
|
|
| |
Dynamic range at 30 dB gain | dB | 18 |
|
|
| |
|
|
|
|
|
| |
Dynamic range at 21 dB gain | dB | 25 |
|
|
| |
|
|
|
|
|
| |
Noise figure | dB | 6 |
|
|
| |
|
|
|
|
|
|
|
NETWORK MANAGEMENT |
|
|
|
|
|
|
|
|
|
|
|
| |
Monitorable parameters |
| Internal voltage supply, internal current drain, |
| |||
| internal temperature, ICS switch |
| ||||
|
|
| ||||
|
|
|
|
|
|
|
Test sockets |
|
|
|
|
|
|
|
|
|
|
|
|
|
Test socket 1 (on amplifier input), | dB | 20 |
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
| Possibility to feed in return path signals |
Test socket 2 (on amplifier output), directional coupler | dB | 20 |
|
| ||
|
|
|
|
|
| incoming return path signal can be measured |
|
|
|
|
|
| |
Test socket 3 (in return path amplifier), directional coupler | dB | 10 |
|
| Attenuation relative to return path input | |
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
Nominal input voltage | V AC | 230 |
|
|
| |
|
|
|
|
|
| |
Mains frequency range | Hz |
|
|
| ||
|
|
|
|
|
|
|
Max. remote feed current | A | - |
|
| 7 | per input or output |
|
|
|
|
|
|
|
Max. remote feed current, local insertion | A | - |
|
| 10 |
|
|
|
|
|
|
| |
Power consumption (without monitoring) | W | 17.5 |
|
| Return path amplifier active | |
|
|
|
|
|
|
|
GENERAL |
|
|
|
|
|
|
|
|
|
|
| ||
Classification according to KDG 1 TS 140 |
| D(4.4) |
|
| ||
|
|
|
|
| ||
Ambient temperature range | °C |
| ||||
|
|
|
|
| ||
RF connections |
| PG 11 |
|
| ||
|
|
|
| |||
Test sockets |
|
| ||||
|
|
|
|
| ||
Housing protection class (to EN 60529) |
| IP 54 |
|
| ||
|
|
|
|
| ||
Dimensions (W x H x D) | mm | 238 × 86 × 189 |
|
| ||
|
|
|
|
| ||
Packing unit/weight | pc./kg | 1(10)/2.2 |
|
|
VOS 952-1G/953-1G
•Latest
•Innovative operational concept:
-Settings via slide switches
-Device settings can be reproduced exactly
-Fewer
•Very high output level at lowest intermodula- tion products
•
•15 MHz high pass can be activated in the return path
•Ingress Control Switch (ICS)
•Monitorable with HMS or DOCSIS (option)
•Insert position for additional functions in the forward path (e.g.
•
•Directional coupler test socket on amplifier output and in return path
•Test signals can be coupled in for the return path
•Highly efficient
•VOS
•VOS
•Surge absorbers on all RF connections and in
•
•Test sockets:
House connection amplifiers
The compact,
Monitoring via DOCSIS transponder
If fitted with the optional monitoring transponder TVM 1000/H, the amplifiers VOS
Bridgeable diplex filter
Bridging plugs enable variation of the frequency range between
Flexible return path
In the latest generation, the return path can be operated either actively or passively.
1) CENELEC: 41 channels 2) When the 15 MHz high pass is connected, the dynamic range increases by 3 dB 3) Settable in
11