Kathrein manual VOS 952-1G/953-1G DESCRIPTION, Data, House connection amplifiers, VGO 939-1G

Models: VOS 952-1G/953-1G

1 11
Download 11 pages 11.84 Kb
Page 6
Image 6
DATA

VGO 939-1G/

 

 

VGF 939-1G

 

DATA

Technical Data

 

 

Type

VGO 939-1G VGF 939-1G

Notes

VOS 952-1G/953-1G DESCRIPTION

Order no.

 

24410101

 

 

24410100

 

 

 

 

 

 

 

 

 

 

Locally fed

Remotely fed

 

 

 

 

 

 

 

 

FORWARD PATH

 

 

 

 

 

 

 

 

 

 

 

 

 

Frequency range

MHz

85-1000

 

 

 

 

 

 

 

 

 

Gain

dB

40

 

 

 

 

 

 

 

 

 

 

Gain setting range, interstage ³)

dB

32-40

 

 

 

 

 

 

 

 

 

 

Amplitude response

dB

±0.5

 

 

85-1000 MHz, at 25 °C

 

 

 

 

 

 

 

Amplitude response (additional, 862-1000 MHz)

dB

-0.5

 

 

at 25 °C

 

 

 

 

 

 

 

Attenuation setting range, on input ³)

dB

0-26

 

 

 

Pre-emphasis setting range, at input ³) or interstage

dB

0-26 or 0/4/8

 

 

Return loss, as of 40 MHz

dB

18-1.5/oct.

 

 

 

 

 

 

 

 

 

Noise figure

dB

4

 

 

at 40 dB gain

 

 

 

 

 

 

 

Max. operational level: CENELEC raster ¹)

dBµV

116/118

 

CTB: 60 dB/CSO: 60 dB (pre-emphasis 4 dB)

 

 

 

 

 

 

 

Hum modulation ratio

dB

-

 

 

60/70

AT 7 A, 5-65/85-1000 MHz

 

 

 

 

 

 

 

RETURN PATH

 

 

 

 

 

 

 

 

 

 

 

 

 

Frequency range

MHz

5-65

 

 

 

 

 

 

 

 

 

Gain (input stage bridged), active operation

dB

30 (21)

 

 

 

 

 

 

 

 

 

Gain, passive operation

dB

-2

 

 

 

 

 

 

 

 

 

Amplitude response

dB

0.5

 

 

 

 

 

 

 

 

 

Attenuation setting range, at input or interstage ³)

dB

0/4/8 or 0-16

 

 

 

 

 

 

 

 

Pre-emphasis setting range, interstage

dB

0/3/6

 

 

 

 

 

 

 

 

 

Ingress Control Switch (ICS)

dB

8/> 40

 

 

attenuated/switched-off

 

 

 

 

 

 

Max. output level at 30 and 21 dB gain

dBµV

107/116

 

60 dB IMod2/IMod3 (EN 60728-3/50083-5)

 

 

 

 

 

 

Max. output level

dBµV

120

 

 

According to KDG 1 TS 140 (full system load)

 

 

 

 

 

 

Input level density

dBµV/Hz

-8

 

 

CINR at 50 dB (EN 60728-3/item 4.7)

 

 

 

 

 

 

Dynamic range at 30 dB gain (5-65 MHz) ²)

dB

18

 

 

 

 

 

 

 

 

 

Dynamic range at 21 dB gain (5-65 MHz) ²)

dB

25

 

 

 

 

 

 

 

 

 

Noise figure

dB

6

 

 

 

 

 

 

 

 

 

 

NETWORK MANAGEMENT

 

 

 

 

 

 

 

 

 

 

 

 

Monitorable parameters

 

Internal voltage supply, internal current drain,

 

 

internal temperature, ICS switch

 

 

 

 

 

 

 

 

 

 

 

Test sockets

 

 

 

 

 

 

 

 

 

 

 

 

 

Test socket 1 (on amplifier input), bi-directional

dB

20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Possibility to feed in return path signals

Test socket 2 (on amplifier output), directional coupler

dB

20

 

 

(5-65 MHz); if button is kept pressed, the

 

 

 

 

 

 

incoming return path signal can be measured

 

 

 

 

 

 

Test socket 3 (in return path amplifier), directional coupler

dB

10

 

 

Attenuation relative to return path input

 

 

 

 

 

 

 

SWITCHED-MODE POWER SUPPLY

 

 

 

 

 

 

 

 

 

 

 

 

 

Nominal input voltage

V AC

230

 

 

32-72

 

 

 

 

 

 

 

Mains frequency range

Hz

50-60

 

 

 

 

 

 

 

 

 

 

Max. remote feed current

A

-

 

 

7

per input or output

 

 

 

 

 

 

 

Max. remote feed current, local insertion

A

-

 

 

10

 

 

 

 

 

 

 

Power consumption (without monitoring)

W

17.5

 

 

Return path amplifier active

 

 

 

 

 

 

 

GENERAL

 

 

 

 

 

 

 

 

 

 

 

Classification according to KDG 1 TS 140

 

D(4.4)

 

 

 

 

 

 

 

Ambient temperature range

°C

-20 to +55

 

data-conform operation

 

 

 

 

 

RF connections

 

PG 11

 

 

 

 

 

 

Test sockets

 

F-type connector

 

 

 

 

 

 

Housing protection class (to EN 60529)

 

IP 54

 

 

 

 

 

 

 

Dimensions (W x H x D)

mm

238 × 86 × 189

 

 

 

 

 

 

 

Packing unit/weight

pc./kg

1(10)/2.2

 

 

VOS 952-1G/953-1G

Latest GaAs-MMIC technology

Innovative operational concept:

-Settings via slide switches

-Device settings can be reproduced exactly

-Fewer plug-in cards and variable attenuators needed

Very high output level at lowest intermodula- tion products

Built-in active return path with various setting possibilities

15 MHz high pass can be activated in the return path

Ingress Control Switch (ICS)

Monitorable with HMS or DOCSIS (option)

Insert position for additional functions in the forward path (e.g. de-emphasis)

Bi-directional test socket on amplifier input with inductive coupling

Directional coupler test socket on amplifier output and in return path

Test signals can be coupled in for the return path

Highly efficient switched-mode power supply unit

VOS 952-1G - locally fed, F-type connectors

VOS 953-1G - remotely fed (auto-supply), F-type sockets

Surge absorbers on all RF connections and in switched-mode power supply unit

Die-cast housing

Test sockets: F-type sockets

House connection amplifiers

The compact, price-optimised house connection amplifiers 952-1G and VOS 953-1G were designed for application in modern HFC networks. Great value was set upon a high dynamic range for Interstage operation as well as upon a cost-efficient operation concept with slide switches.

Monitoring via DOCSIS transponder

If fitted with the optional monitoring transponder TVM 1000/H, the amplifiers VOS 952-1G/953-1G can be monitored via DOCSIS protocol. Monitoring with HMS Both amplifiers can be flexibly integrated into monitoring systems which operate with the widespread HMS protocol.

Bridgeable diplex filter

Bridging plugs enable variation of the frequency range between 47-1000 MHz and 85-1000 MHz making it possible to carry out transmission in BAND I in the forward path (without return path).

Flexible return path

In the latest generation, the return path can be operated either actively or passively.

1) CENELEC: 41 channels 2) When the 15 MHz high pass is connected, the dynamic range increases by 3 dB 3) Settable in 2-dB steps using slide switches

11

Page 6
Image 6
Kathrein manual VOS 952-1G/953-1G DESCRIPTION, Data, House connection amplifiers, Monitoring via DOCSIS transponder