Accessories
Accessories
EAC 90-1G, 93-1G, 94-1G – Tap-off cards
•
•When inserted in the amplifier's input section these modules can be used to configure a
EBC 90-1G – Splitter, 2-way
Type |
| EAC | EAC | EAC | EBC | |
| ||||||
|
| |||||
|
|
|
|
|
| |
Order no. |
| 24510116 | 24510115 | 24510114 | 24510113 | |
|
|
|
|
|
| |
Frequency range | MHz | |||||
|
|
|
|
|
| |
Through loss ¹) | dB | < 1.3 | < 2.1 | < 0.5 | < 3.6 | |
|
|
|
|
| ||
Through loss ¹) | dB | < 1.3 | < 2.3 | < 0.6 | < 3.8 | |
|
|
|
|
| ||
Through loss ¹) |
| < 1.5 | < 2.6 | < 0.9 | < 3.9 | |
| ||||||
|
|
|
|
| ||
|
|
|
|
|
| |
|
|
|
|
| Like | |
Tap loss | dB | 10 | 6 | 20 | through | |
|
|
|
|
| loss | |
|
|
|
|
|
| |
Decoupling | dB | > 28 | > 23 | > 38 | > 28 | |
|
|
|
|
|
| |
Decoupling | dB | > 26 | > 23 | > 33 | > 22 | |
as of | ||||||
|
|
|
|
| ||
|
|
|
|
|
| |
Decoupling |
| > 24 | > 23 | > 30 | > 20 | |
as of |
| |||||
|
|
|
|
| ||
Decoupling |
| > 22 | > 20 | > 28 | > 18 | |
as of |
| |||||
|
|
|
|
|
1)The through loss is the signal loss between the unit's output and output 1 when the insert is inserted in the output section insertion point or between the unit's input and the tap output when the insert is inserted in the unit's input configuration section
EBC 00-1G and EBC 01E-1G – Null cards (output, input)
•
•EBC
•EBC
Type |
| EBC | EBC |
|
|
|
|
Order no. |
| 24510121 | 24510119 |
|
|
|
|
Frequency range | MHz | ||
|
|
|
|
Through loss ¹) | dB | < 0.5 | < 0.5 |
|
|
|
|
1)The through loss is the signal loss between the unit's output and output 1 when the insert is inserted in the output section insertion point or between the unit‘s input and the tap output when the insert is inserted in the unit's input section (input configuration section)
ERC 22 - C-line pre-emphasis equaliser
•Generates
•For use in the amplifiers VGP 9041/VGF 9040
•Application in the universal input insert position ("Forward 1")
Type |
| ERC 22 |
|
|
|
Order no. |
| 24510085 |
|
|
|
Transmission range | MHz | |
|
|
|
Nominal impedance | Ω | 75 |
|
|
|
| For | |
|
|
|
Basic loss (at 862 MHz) | dB | 1 |
|
|
|
Return loss | dB | 23 |
|
|
|
ERZ 940 – De-emphasis equaliser
•
Type |
| ERZ 940 |
|
|
|
Order no. |
| 24510059 |
|
|
|
Transmission range | MHz | |
|
|
|
Nominal impedance | Ω | 75 |
|
|
|
dB | 7 ± 1 | |
|
|
|
Basic loss (at 47 MHz) | dB | 0.3 |
|
|
|
Return loss | dB | |
|
|
|
ERZ 630 – Equaliser
•Equaliser
•Switchable in
Type |
| ERZ 630 | |
|
|
| |
Order no. |
| 24510108 | |
|
|
| |
Transmission range | MHz | ||
|
|
| |
Nominal impedance | Ω | 75 | |
|
|
| |
Basic loss (at 47/630) | dB | 0.5/1.5 | |
|
|
| |
Equalisation, adjustable in | dB | ||
|
|
ERS 800 – System equaliser
•System equaliser for use in special applications
•Characteristics:
-
-
Principal frequency response curve ERS 800
|
|
|
| MHz |
|
|
|
|
0 | 47 100 | 200 | 300 | 400 | 500 | 600 | 700 | 800 862 |
0 |
|
|
|
|
|
|
|
|
1 |
|
|
|
|
|
|
|
|
2 |
|
|
|
|
|
|
|
|
dB 3 |
|
|
|
|
|
|
|
|
4 |
|
|
|
|
|
|
|
|
5 |
|
|
|
|
|
|
|
|
6 |
|
|
|
|
|
|
|
|
7 |
|
|
|
|
|
|
|
|
Type |
| ERS 800 | |
|
|
| |
Order no. |
| 24510109 | |
|
|
| |
Transmission range | MHz | ||
|
|
| |
Nominal impedance | Ω | 75 | |
|
|
| |
dB | 3/(4) | ||
|
| ||
|
|
| |
dB | 3 | ||
the range | |||
|
| ||
|
|
| |
Basic loss (at 862 MHz) | dB | 0.5 | |
|
|
| |
Return loss | dB | > 15 | |
|
|
|
18 |