Monitoring transponder HMS protocol, frequency-agile

Monitoring transponder for compact amplifiers, house connec- tion amplifiers and optical compact receivers (see table)

Monitors various parameters such as voltage, current drain and internal temperature

Controls the Ingress Control switch in correspondingly equip- ped devices

Transmission in the HMS protocol

Frequency-agile in range 5-42 MHz

Type

 

TVM 850/H

 

 

 

Order no.

 

26210077

 

 

 

Input frequency range

MHz

75-90.5

 

 

 

Input level range

dBµV

50-95

 

 

 

Output frequency range

MHz

5-42

 

 

 

Max. output level

dBµV

105

 

 

 

Power consumption

W

1

 

 

 

Transmission protocol

 

HMS

 

 

 

 

 

VGO 939, VGF 939, VGO 939-1G, VGF 939-1G, VOS 952/953, VOS 952-1G,

Suitable for

 

VOS 953-1G, ORA 9022, ORA 9022-1G, ORA 920/921, VGP 9033,

 

 

VGP 9033-1G, VGP 9041, VGF 9030/9040

 

 

 

TVM 1000 - Monitoring transponder DOCSIS/

EuroDOCSIS, frequency-agile

Monitoring transponder for compact/house connection amplifiers and optical com- pact receivers (see table)

Monitors various parameters such as voltage, current drain and internal temperature

Controls the Ingress Control switch in correspondingly equipped devices

Transmission in DOCSIS or EuroDOCSIS protocol

Frequency-agile in range 5-65 MHz and 90-862 MHz

Type

 

TVM 1000

 

 

 

Order no.

 

26210086

 

 

 

Input frequency range

MHz

90-862

 

 

 

Input level range

dBµV

48-78

 

 

 

Output frequency range

MHz

5-65

 

 

 

Max. output level

dBµV

113-118

 

 

 

Power consumption

W

3.5

 

 

 

Transmission protocol

 

DOCSIS/EuroDOCSIS 2.0

 

 

 

 

 

VGO 939, VGO 939-1G, VGF 939, VGF 939-1G, VOS 952/953, VOS 952-1G,

Suitable for

 

VOS 953-1G, ORA 9022, ORA 9022-1G, ORA 920/921, VGP 9033 as of version A03

 

 

(Nov. 2008), VGP 9033-1G, VGP 9041 as of version A02 (Nov. 2008), VGF 9030/9040

 

 

 

HTE 10 - Hand-held unit

With the HTE 10 hand-held unit one is able to adjust correspondingly equipped devices on site. Using the 'Up' and 'Down', 'Menu' and 'Enter' buttons, one is able to change and set the values on the 4-line display. The display is illuminated and easy to read.

The hand-held unit presents the following functions:

All appropriately equipped devices or modules can be adjusted and operated

All settings are displayed

The last settings are saved (copy function)

The hand-held unit is power-supplied by the respective module

Distances:

-Data transfer between HTE 10 and the device or module over max. 14 m

-Standard connection cable: 2 m (included in delivery scope)

-Can be extended to 14 m (TDK 10)

4-line display, illuminated

Language: English

Splash-proof/shock-proof

Ambient conditions:

-Ambient temperature: -20 to +50 °C

-Suitable for outdoor application

-Protection category: IP 54

Control signal: Serial, RS 232

Connection: Sub D, 9-pin

Accessories (not included in delivery scope):

TDK 10 (Order no. 26210054): Connection cable 14 m

TDK 12 (Order no. 26210076): PC connection cable for HTE 10 (for software updates)