Self-Help Guide
|
|
|
|
PROBLEM | PROBABLE |
| SOLUTION |
| CAUSE |
| (Follow Sequentially) |
Motor runs but will not | Tub not set up properly. | Place components in tub per the following: | |
pump oil. |
| 1. | Sump screen on the very bottom |
|
| 2. Filter paper over sump screen (Lie it flat | |
|
|
| on the bottom, creasing the sides). |
|
| 3. Hold down ring (ensure paper is not | |
|
|
| folded, lock hold down ring into place |
|
| 4. | ensuring a tight seal). |
|
| Sprinkle Acidox powder evenly over filter | |
|
| 5. | paper (1bag per 40 lbs. of oil). |
|
| Crumb basket for large debris. | |
| Tub not connected to the motor | 1. | Remove tub from the filter cart |
| housing properly |
| completely by pulling the release handle |
|
|
| located on the bottom of the filter control |
|
| 2. | panel. |
|
| Place the tub onto the filter cart by first | |
|
|
| inserting the rear lip under the filter cart |
|
|
| frame and then laying down the front of |
|
| 3. | the tub flat onto the cart. |
|
| Connect the tub to the motor housing by | |
|
|
| pulling together the handles on the tub |
|
|
| and the handles on the motor housing |
|
|
| (NOTE: Verify tight connection by pushing |
|
|
| back on the tub). |
| Filter not connected inside of | 1. | Ensure filter assembly is rolled straight |
| cabinet | 2. | onto the rails inside of the cabinet. |
|
| Push filter assembly back as far as | |
|
| 3. | possible |
|
| Ensure quick disconnect fitting on top of | |
|
|
| filter connects automatically with quick |
|
| 4. | connect fitting inside of cabinet. |
|
| Pull on filter lightly to ensure a tight | |
|
|
| connection |
| Valve not switched to “Oil to Fryer” | 1. | Set the black knob in the middle of the |
|
| 2. | filter control panel to the far right. |
|
| Try to filter again. | |
| If there’s more than one fryer, | 1. | Open the door of the fryer you wish to |
| return valve not open. | 2. | filter. |
|
| Pull the return valve handle (small black | |
|
| 3. | knob) out as far as possible. |
|
| Attempt to filter again. When completed, | |
|
|
| push the black knob in as far as possible |
|
|
| to close. |
– 6 –