Keating Of Chicago 1-800 Self-HelpGuide, Problem, Probable, Solution, Cause, Follow Sequentially

Models: 1-800

1 12
Download 12 pages 63.79 Kb
Page 8
Image 8

Self-Help Guide

 

 

 

 

PROBLEM

PROBABLE

 

SOLUTION

 

CAUSE

 

(Follow Sequentially)

Motor runs but will not

Tub not set up properly.

Place components in tub per the following:

pump oil.

 

1.

Sump screen on the very bottom

 

 

2. Filter paper over sump screen (Lie it flat

 

 

 

on the bottom, creasing the sides).

 

 

3. Hold down ring (ensure paper is not

 

 

 

folded, lock hold down ring into place

 

 

4.

ensuring a tight seal).

 

 

Sprinkle Acidox powder evenly over filter

 

 

5.

paper (1bag per 40 lbs. of oil).

 

 

Crumb basket for large debris.

 

Tub not connected to the motor

1.

Remove tub from the filter cart

 

housing properly

 

completely by pulling the release handle

 

 

 

located on the bottom of the filter control

 

 

2.

panel.

 

 

Place the tub onto the filter cart by first

 

 

 

inserting the rear lip under the filter cart

 

 

 

frame and then laying down the front of

 

 

3.

the tub flat onto the cart.

 

 

Connect the tub to the motor housing by

 

 

 

pulling together the handles on the tub

 

 

 

and the handles on the motor housing

 

 

 

(NOTE: Verify tight connection by pushing

 

 

 

back on the tub).

 

Filter not connected inside of

1.

Ensure filter assembly is rolled straight

 

cabinet

2.

onto the rails inside of the cabinet.

 

 

Push filter assembly back as far as

 

 

3.

possible

 

 

Ensure quick disconnect fitting on top of

 

 

 

filter connects automatically with quick

 

 

4.

connect fitting inside of cabinet.

 

 

Pull on filter lightly to ensure a tight

 

 

 

connection

 

Valve not switched to “Oil to Fryer”

1.

Set the black knob in the middle of the

 

 

2.

filter control panel to the far right.

 

 

Try to filter again.

 

If there’s more than one fryer,

1.

Open the door of the fryer you wish to

 

return valve not open.

2.

filter.

 

 

Pull the return valve handle (small black

 

 

3.

knob) out as far as possible.

 

 

Attempt to filter again. When completed,

 

 

 

push the black knob in as far as possible

 

 

 

to close.

– 6 –

Page 8
Image 8
Keating Of Chicago 1-800 owner manual Self-HelpGuide, Problem, Probable, Solution, Cause, Follow Sequentially