Keating Of Chicago 14 BB Gas manual Bb Gas Recovery Fryer, Description, Specifications, Instant

Models: 14 BB Gas

1 2
Download 2 pages 23.05 Kb
Page 2
Image 2
14 BB GAS

14 BB GAS

14 BB GAS

RECOVERY® FRYER

DESCRIPTION

The Keating Instant Recovery® 14 BB Fryer consists of a frying vessel 14" sq., having a splash deck and a splash back installed in a cabinet equipped with gas burners and an automatic temperature control mechanism, all arranged and designed for the proper frying of food.

SPECIFICATIONS

Fryer Vessel: shall have coved seamless corners and be drawn from 18 gauge stainless steel, shall have a shortening capacity of 38 pounds, shall be equipped with three 18 gauge horizontal heat transfer tubes spaced above the bottom of the vessel so that the bottom is unheated and the food particles collecting in this bottom zone are unheated and therefore do not carbonize. The frying vessel shall be polished to inhibit carbon build-up and facilitate wasy clean-up.The heat transfer tubes shall be 3" wide and 5" high. The bottom of the vessel shall slope toward the front where it shall be equipped with a 1" Teflon core 1/4 turn, drain valve, so arranged that the shortening can be drained into a receiv- ing vessel placed in front of the fryer.

Splashdeck shall slope toward the shortening containing vessel.

The splash deck shall be made of 16 gauge 304 stainless steel.

Splashback shall be made of 18 gauge 304 stainless steel, shall completely cover the sides of the flue.

Cabinet: shall be made of 18 gauge stainless steel. The cabinet shall be rigid in construction and shall have four 8" adjustable legs. A door made of 22 gauge 304 stainless steel shall cover the front of the cabinet and shall extend from the bottom of the fryer to the panel, and above the panel shall be a canopy. The door shall be the full width of the cabinet. No additional space is required for the door to open a full 90 degrees. A stainless steel flue deflector is provided for installing onto the flue back.

Heat Transfer Tubes to be three, made of stainless steel polished to a # 7 mirror finish.

Thermostat shall be close range, hydraulic type and be accu- rate to ±3°F from 300° to 350°F with stainless steel bulb. Application of this thermostat is patented by Keating.

Hi-Limit Control shall be manually resettable type with stainless steel bulb.

100% Safety Shut Off shall be flame switch type with combi- nation control gas valve.

Melt Cycle to be standard on "BB" fryers, allowing the safe melting of solid shortening. Fryer is to be left in the Melt Cycle mode until oil completely covers heat transfer tubes.

Indicating Lights & Switches. Power on switch, power on light, push to light switch, pilot on light, fry off melt switch.

Standard Accessories to include one pair 4 mesh baskets, grid screen over heat transfer tubes, drain clean out rod and sample of Keating Klenzer and Sea Powder.

Electrical Requirements: Supply Voltage 120V 60Hz Control Voltage 24V 60Hz. 120 VAC 9ft. (1.5 m) grounded cord set provided.

Gas Requirements to install are 3/4" male NPT connection and 4" water column pressures natural and 10" for LP gas at the fryer burner manifold. Supply pressure to fryers must be 7" (natural gas) and 11" (LP) water column.

Special Order Options may include battery, common mani- fold, rear drain, casters, cover, thermostat seal, spark ignition, portable filter, central filter, Safe & Easy filter, full or triple size baskets, security package, and 17" flue riser.

INSTANT

 

 

 

Oil

BTU

 

 

 

Ship

 

 

Model No. and Description

Capacity

Input

Height

Depth

Width

Wt.

 

 

 

 

 

 

 

 

 

 

 

 

 

14

BB Nat Gas

38 lbs.

87,000

46 1/2"

28 3/4"

15 3/8"

170 lbs.

 

 

 

 

 

 

 

 

 

 

 

 

 

14

BB LP Gas

38 lbs.

90,000

46 1/2"

28 3/4"

15 3/8"

170 lbs.

 

 

 

 

 

 

 

 

 

 

 

 

 

14

Safe & Easy

-

-

46 1/2"

32 5/8"

15 3/8"

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KEATING OF CHICAGO, INC. Toll Free 1-800-KEATING www.keatingofchicago.com

As continuous product improvement occurs, specifications may be changed without notice.

Printed in U.S.A.

14BB2007

7/07

Page 2
Image 2
Keating Of Chicago 14 BB Gas manual Bb Gas Recovery Fryer, Description, Specifications, Instant