TROUBLESHOOTING CHART
The following diagnosis is only to be used as a guide to qualified service personnel. Keating recommends that you use a qualified service company. Call
COMMON PROBLEMS | SOLUTIONS (FOLLOW IN SEQUENCE) | |
|
| |
Water always filling | 1. Clean sensors thoroughly with brush and vinegar. | |
| 2. | Adjust the sensitivity of the B Board (for the top sensor) fully clockwise. |
| 3. | If filling persists, ground out the top sensor (if filling stops, replace sensor – |
|
| Part #010212). |
| 4. | If filling persists after grounding the sensor, replace the B Board (Part |
|
| #001166). |
|
|
|
Water never fills | 1. | Turn water switch (far right) ‘on.’ |
| 2. | Clean sensors thoroughly with the brush and vinegar. |
| 3. | Adjust the sensitivity of the B Board (for the top sensor) fully counter |
|
| clockwise (follow sevice instruction sheet - Setting Water Level Control). |
| 4. | Remove the wire from the top sensor. If filling begins, replace sensor (Part # |
|
| 010212). |
| 5. | If water does not fill, place a jumper wire across terminals A & C on the B |
|
| Board. If filling begins, replace B Board (Part # 001166). |
| 6. | If water does not fill, replace water solenoid (Part # 008133). |
|
| |
Timers counting down in the | 1. Reset the timer (see pages | |
wrong mode (not minutes or |
|
|
seconds) |
|
|
|
|
|
Water leaking in the rear of | 1. | Replace fill hose (Part #037390 – sold per foot) |
the pasta cooker |
|
|
|
|
|
Breakers continue to trip | 1. | Ensure all wires to the contactors, breakers and elements are tight. |
| 2. | Verify water is not getting on any components. |
| 3. | Check contactors for proper operation. |
| 4. | Check continuity of heating elements. |
| 5. | Replace breaker. |
|
|
|
Heating elements won’t | 1. | Verify operating instructions in the manual. |
come on | 2. | Clean sensors with brush and vinegar. |
| ||
| 3. | Adjust sensitivity of the A Board (for the lower sensor) fully clockwise (follow |
|
| service instruction sheet - Setting Water Level Control). |
| 4. | Place the wire attached to the lower sensor to the ground (if heating begins, |
|
| replace sensor – Part #010212). |
| 5. | If heating does not being, place a jumper wire across terminals A&C on the A |
|
| Board. If heating begins, replace the A Board (Part #001167). |
|
|
|
11