S E R V I C E I N S T R U C T I O N S

www.keatingofchicago.com

1-800-KEATING

REMOVAL AND REPLACEMENT OF FRONT DRAIN FRYER VESSEL (MODELS WITH UNI-POT) CONTINUED

page 2

9.Remove flue from fryer vessel by removing six screws out of tabs. Inspect flue for cracks or damage and replace if necessary.

10.Remove drain valve from fryer vessel.

REPLACEMENT:

1.Slide flue onto tabs on back of new fryer vessel until it contacts back of vessel. Drill holes into vessel tabs through existing holes in flue and fasten flue to vessel tabs with six sheet metal screws and set on floor next to old vessel.

2.Replace drain valve on new fryer vessel after applying high temperature sealant on vessel threads.

3.Remove gas manifold with support brackets from vessel by removing four screws and lockwashers joining brackets

to sides of vessel. Leave constant and runner pilot tubing and gas manifold connected to manifold brackets and assemble to new vessel.

4.Carefully lower vessel and flue into cabinet. Check fryer vessel fit in cabinet before proceeding with assembly.

5.Replace splashback onto vessel with sheet metal screws and pop rivets.

6.Replace canopy onto cabinet with two sheet metal screws.

7.Tighten union in tailpiece assembly.

8.Replacement of components:

a.Replace Hi-Limit control bulb into vessel.

b.Replace thermostat bulb into vessel.

Part #031289

Rev. 1 ECO 2110

Date 6/11/98

Page 2
Image 2
Keating Of Chicago CMG, 031289 manual Replacement