Electrical Shock Hazard

Plug into a grounded 3 prong outlet.

Do not remove ground prong.

Do not use an adapter.

Do not use an extension cord.

Faimure to follow these instructions can result in death,

fire, or emectrical shock.

A 120-volt, 60-Hz., AC-only, 15- or 20-amp, fused electrical supply is required. A time-delay fuse or circuit breaker is recommended. It is recommended that a separate circuit serving only this appliance be provided.

This washer is equipped with a power supply cord having a 3 prong grounding plug.

To minimize possible shock hazard, the cord must be plugged into a mating, 3 prong, grounding-type outlet, grounded in accordance with local codes and ordinances. If a mating outlet is not available, it is the personal responsibility and obligation of the customer to have the properly grounded outlet installed by a qualified electrician.

If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate.

Do not ground to a gas pipe.

Check with a qualified electrician if you are not sure the washer is properly grounded.

Do not have a fuse in the neutral or ground circuit.

GROUNDING mNSTRUCTJONS

For a grounded, cord-connected washer:

This washer must be grounded, in the event of a maIfunction or breakdown, grounding wiII reduce the risk of electrical shock by providing a path of Ieast resistance for electric current. This washer is equipped with a cord having an equipment-grounding conductor and a grounding pIug. The plug must be plugged into an appropriate outlet that is

properIy instalIed and grounded in accordance with all local codes and ordinances.

WARNING: improper connection of the equipment- grounding conductor can result in a risk of electric shock. Check with a qualified electrician or serviceman if you are in doubt as to whether the appliance is properly grounded.

Do not modify the piug provided with the appliance - if it will not fit the outlet, have a proper outlet installed by a qualified electrician.

For a permanently connected washer:

This washer must be connected to a grounded metal, permanent wiring system, or an equipment grounding conductor must be run with the circuit conductors and connected to the equipment-grounding terminal or lead on the appliance.

Page 8
Image 8
Kenmore 110.4587, 110.4586 manual Grounding mNSTRUCTJONS