3.Put the new orifice into the orifice removal tool (B), and then insert the tool into the burner opening and tighten the new orifice into the valve.

Repeat this step for all four burners.

Make sure you are using the correct orifice, which is marked “1.37”. (Fig. 3)

4.Rotate the air shutter opening from the

LP setting to the NG setting. LP: 1/4" open

NG: 1/6" to 1/8" open (Fig. 4)

Natural Gas Hose Connection

B

1.37

Fig. 3

Air shutter opening to adjust

Fig. 4

Remove the LP gas hose and regulator using a wrench, and attach the natural gas hose in it's place. (Fig. 5)

NG Hose

LP gas hose and regulator

Fig. 5

24

Page 24
Image 24
Kenmore 148.1615421 manual Natural Gas Hose Connection