blockthedischargeopeningorhinderaccesstothemanual relieflever(Figure9). Ensureadischargepipeisinstalled intotheT&Pvalvedischargeopeningpertheinstructions thismanual.

4.Locatethehotwater(outlet)&coldwater(inlet)pipestothe

waterheater.

5.Locatetheslit runningthelengthof a sectionof pipe insulation.

6.Spreadtheslitopenandsliptheinsulationoverthecold water(inlet)pipeApplygentlepressurealongthelengthof. theinsulationtoensurethatitisfullyseatedaroundthepipe. Also,ensurethatthebaseoftheinsulationisflushwiththe waterheaterOnceseated,securetheinsulationwithduct. tape,electricaltape,orequivalent.

7.Repeatsteps5and6forthehotwater(outlet)pipe.

8.Addadditionalsectionsofpipeinsulationasneeded.

T&PReliefValveInsulation

Thevalvemustbemarkedwithamaximumsetpressurenotto exceedthemarkedhydrostaticworkingpressureofthewater heater(150psi=1,035kPa)andadischargecapacitynottess thanthewaterheaterinputrateasshownonthemodelrating plate(Forelectricheaters,wattsx. 3.412equalsBtu/hrinput rate)

Forsafeoperationofthewaterheater,thereliefvalvemustnot

beremovedfromitsdesignatedopeningnorplugged.

Thetemperature-pressurereliefvalvemustbeinstalleddirectly intothefittingofthewaterheaterdesignedforthereliefvalve. Positionthevalvedownwardandprovidetubingsothatany dischargewillexitonlywithin6inches(153mm)above,oratany distancebelowthestructuralfloor.Becertainthatnocontactis

madewithanyliveelectricalpart.Thedischargeopeningmust

notbeblockedorreducedinsizeunderanycircumstances. Excessivelength,over30feet(9.14m),oruseof morethan fourelbowscancauserestrictionandreducethedischarge capacityofthevalve.

efLever

Relief Valve

Drain Line

FIGURE 9.

Temperature-Pressure Relief Valve

Explosion Hazard

Temperature-pressure relief valve must comply with ANSI Z21.22 CSA 4.4 andASME code.

Properly sized temperature-relief valve must be installed in opening provided.

Can result in overheating and excessive tank pressure.

Can cause serious injury or death.

This heater is provided with a properly certified combination temperature - pressure relief valve by the manufacturer.

The valve is certified by a nationally recognized testing laboratory that maintains periodic inspection of production of listed equipment of materials as meeting the requirements for Relief Valves for Hot Water Supply Systems, ANSI Z21.22 • CSA 4.4, and the code requirements of ASME.

If replaced, the valve must meet the requirements of local codes, but not less than a combination temperature and pressure relief valve certified as indicated in the above paragraph.

Water Damage Hazard

Temperature-pressure relief valve discharge

pipe must terminate at adequate drain.

No valve or other obstruction is to be placed between the relief valve and the tank. Do not connect tubing directly to discharge drain unless a 6 inch air gap is provided. To prevent bodily injury, hazard to life, or property damage, the relief valve must be allowed to discharge water in quantities should circumstances demand. If the discharge pipe is not connected to a drain or other suitable means, the water flow may cause property damage.

The Discharge Pipe:

Shall not be smaller in size than the outlet pipe size of the valve, or have any reducing couplings or other restrictions.

Shall not be plugged or blocked.

Shall be of material listed for hot water distribution.

Shall be installed so as to allow complete drainage of both the temperature-pressure relief valve, and the discharge pipe.

Shall terminate a maximum of six inches above a floor drain or external to the building. In cold climates, it is recommended that the discharge pipe be terminated at an adequate drain inside the building.

Shall not have any valve between the relief valve and tank.

ITs5D7.,1[€] :l

Water temperature

over 125°F

 

(52°C) can cause severe burns

 

instantly resulting in severe injury

 

or death.

 

 

 

 

Children, the elderly,

and the

 

physically

or mentally

disabled

 

are at highest riskfor scald injury.

 

Feel water before bathing or

 

showering.

 

 

 

 

Temperature

limiting

valves are

 

available.

 

 

 

 

Read instruction manual for safe

 

temperature

setting.

 

 

11

Page 11
Image 11
Kenmore 153.31242 manual Beremovedfromitsdesignatedopeningnorplugged, EfLever, Temperature-Pressure Relief Valve

153.31242 specifications

The Kenmore 153.31242 is a reliable and efficient air conditioner that combines advanced technology with user-friendly features, making it a popular choice for many homeowners. This model is particularly recognized for its versatility in cooling, perfect for various room sizes and settings, ensuring that users can find optimal comfort at home.

One of the standout features of the Kenmore 153.31242 is its impressive cooling capacity. With a BTU rating suitable for medium to large rooms, it can effectively lower the temperature even on the hottest days. Its ability to quickly cool a space makes it ideal for summer months, allowing users to escape the heat without compromising comfort.

The unit employs a powerful compressor and a fan system designed to distribute air evenly throughout the room. This technology ensures consistent temperature control, eliminating hot spots that are common in less efficient models. Additionally, the air conditioner features multiple cooling speeds and a programmable timer, giving users the flexibility to customize their cooling preferences.

Energy efficiency is another critical characteristic of the Kenmore 153.31242. It is equipped with an Energy Efficiency Ratio (EER) that exceeds the minimum federal standards, consuming less power while effectively cooling the space. This efficiency not only reduces energy costs but also contributes to environmental sustainability, making it an eco-friendly choice.

Moreover, the Kenmore AC unit includes a user-friendly control panel with an easy-to-read display. This panel often incorporates remote control functionality, allowing users to adjust settings from the comfort of their couch or bed. Many models also offer compatibility with smart home systems, providing remote management via mobile devices.

The Kenmore 153.31242 is built with durable materials designed to withstand the test of time. Its robust design emphasizes low maintenance, with washable filters that keep the air clean and reduce allergens, enhancing indoor air quality.

In summary, the Kenmore 153.31242 stands out for its powerful cooling capabilities, energy efficiency, and user-centric features. Combining modern technology with practical functionality, this air conditioner is an excellent choice for anyone looking to maintain a comfortable living environment.