eT_,W =1t,i

Burn hazard

Hotwater discharge.

Keep hands clear of drain valve discharge.

The water passing out of the drain valve may be extremely hot. To avoid being scalded, make sure all connections are tight and that the water flow is directed away from any person.

4.Remove the screw securing the access panel, then remove the panel.

"

FIGURE 33.

5.Fold the insulation back to expose the thermostat.

FIGURE 34.

FIGURE 36.

8.Clean the area around the element opening. Remove any sediment from or around the element opening, inside the tank.

g.If you are cleaning the element you have removed, do so by scraping or soaking in vinegar or a de-liming solution.

Fire Hazard and

Electric Shock Hazard

Do not use replacement elements with any voltage other than shown on the model rating plate.

Failure to use the correct voltage shown on the model rating plate could result in death, serious bodily injury, or property damage.

Replacement elements must (1) be the same voltage and (2)

no greater wattage than listed on the model rating plate affixed to the water heater.

10.A new gasket should be used in all cases to prevent a possible water leak. (See Element Gasket in the Repair Parts List Chart). Place the new element gasket on the thread side of the cleaned or new element and screw into tank, securing tightly using an element wrench.

6.Lift out the tab as shown to unclip the terminal cover from the thermostat. The terminal cover can now be removed from

the thermostat.

LIFT OUT TAB TO

 

 

 

 

 

 

UNCLIP TERMINAL

JACK_

 

 

_'_

 

 

COVER FROM

 

 

 

 

 

 

 

PLASTIC

TABS

ON

TH ERMOSTAT

TERMINAL

COVER

 

 

 

 

 

 

 

 

CLIPPED

TO

\

BOTH SIDES

OF

 

TERMINAL

COVER

 

THERMOSTAT

AT _

HOL IT IN PLACE

 

THIS POINT

 

 

 

 

 

 

 

 

 

_

THERMOSTAT

 

 

 

 

 

BRACKET

 

 

 

 

 

r_-TAN K

 

 

 

LOWER

 

-1

- ELEMENT

 

 

 

 

 

_E

 

 

 

THERMOSTAT

FIGURE 35.

7.Disconnect the two wires on the element and unscrew the old element from the tank.

FIGURE 37.

11.Close the water heater drain valve by turning the handle to the right (clockwise). The drain valve is on the lower front of the water heater.

12.Open the cold water supply valve to the water heater.

NOTE: The cold water supply valve must be left open when the water heater is in use.

13.To insure complete filling of the tank, allow air to exit by opening the nearest hot water faucet. Allow water to run until a constant flow is obtained. This will let air out of the water heater and the piping.

Improper installation and use may result in property damage.

• Fill tank with water before operation.

17

Page 17
Image 17
Kenmore 153.31242 manual ET,W =1t,i, Fire Hazard Electric Shock Hazard

153.31242 specifications

The Kenmore 153.31242 is a reliable and efficient air conditioner that combines advanced technology with user-friendly features, making it a popular choice for many homeowners. This model is particularly recognized for its versatility in cooling, perfect for various room sizes and settings, ensuring that users can find optimal comfort at home.

One of the standout features of the Kenmore 153.31242 is its impressive cooling capacity. With a BTU rating suitable for medium to large rooms, it can effectively lower the temperature even on the hottest days. Its ability to quickly cool a space makes it ideal for summer months, allowing users to escape the heat without compromising comfort.

The unit employs a powerful compressor and a fan system designed to distribute air evenly throughout the room. This technology ensures consistent temperature control, eliminating hot spots that are common in less efficient models. Additionally, the air conditioner features multiple cooling speeds and a programmable timer, giving users the flexibility to customize their cooling preferences.

Energy efficiency is another critical characteristic of the Kenmore 153.31242. It is equipped with an Energy Efficiency Ratio (EER) that exceeds the minimum federal standards, consuming less power while effectively cooling the space. This efficiency not only reduces energy costs but also contributes to environmental sustainability, making it an eco-friendly choice.

Moreover, the Kenmore AC unit includes a user-friendly control panel with an easy-to-read display. This panel often incorporates remote control functionality, allowing users to adjust settings from the comfort of their couch or bed. Many models also offer compatibility with smart home systems, providing remote management via mobile devices.

The Kenmore 153.31242 is built with durable materials designed to withstand the test of time. Its robust design emphasizes low maintenance, with washable filters that keep the air clean and reduce allergens, enhancing indoor air quality.

In summary, the Kenmore 153.31242 stands out for its powerful cooling capabilities, energy efficiency, and user-centric features. Combining modern technology with practical functionality, this air conditioner is an excellent choice for anyone looking to maintain a comfortable living environment.