Installation Instructions (cont'd)
Filling the Water Heater
"Ib fill the water heater with water:
•Close the water heater drain valve by turning the handle to
the right (clockwise). The drain valve is located on the lower front of the water heater.
•Open the cold water supply valve to the water heater.
NOTE: The cold water supply valve must be left open when the water heater is in use.
•_lb insure complete filling of the tank, allow air to exit by
opening the nearest hot water faucet. Allow water to run until a constant flow is obtained. This will let air out of the
water heater and the piping.
Wiring Diagrams
120 VOLT CORD SET
GREEN
A CAUTION | J |
Never use this water heater unless it is completely full J of water. To prevent damage to the tank and heating element, the tank must be filled with water. Water I must flow from the hot water faucet before turning
ON 'power.
•Check all new water piping for leaks. Repair as needed.
Optional Cord Set Wiring
(120Volt)
There may be a cord set supplied with the water heater at the time of manufacture. If not one can be ordered through the Parts Department, see "Repair Parts" section. Refer to figures on this page for wiring diagrams.
120 VOLT WIRING
LuGREEN
.GROONOJl
THERMOSTAT
=
10