Service and Adjustment (cont'd)
Draining
The water heater should he drained if being shut down during freezing temperatures. Also periodic draining and eleanmg of sediment from the tank may be necessary.
Tttrn the gas control knob to the _OFF" position. CLOSE the cold water inlet valve to the water heater.
•OPEN a nearby hot water faucet and leave open to allow for
draining.
Connect a hose to the drain valve and terminate to an ade-
_Uparedrain.
EN the water heater drain valve to allow for tank
draining.
NOTE* If the water heater is going to be shut down and drained for an extended period, the drain valve should be
left open with hose connected allowing water to terminate
to anadequatedrab.
•Close the drain valve.
•Follow instructions in the _Filling The Water Heater" section.
•Follow the lighting instructions in the _Lighting" section to restart the water heater.
Temperature-Pressure Relief
Valve Operation
The
at least once a year.
RELIEF VALVE
&WARNING
When th_ldng the
don, make sum that (I) no one isin frontefor aroundthe
outlet of the
and (2) thatthe
If after manuallyoperatingthe valve,It fails to €om#etety resetandcontinuesto releasewater, immediatelydosethe coldwator inlet to the water heater, followthe draining
instructions,and replace the
Drain Valve Washer
Replacement
NOT_ For replacemtah me a *_" x "/d' • *ti"thick washe*
availableat your nearesthardwarestore.Foro_._ _pla_ meat washers,referto the "PartsOrder Li_ secuom
iFollowurn "OFF"Draining"gas supplyinstructionsto water. heater.
Turning counter clockwise, remove the hex cap below the screw handle.
Remove the washer and put the new one in place.
Screw the handle and cap assembly back into the drain valve and retighten using a wrench. DO NOT OVER TIGHTEN.
•Follow instrucuons in the "Filling The Water Heater" section.
•Check for leaks.
Follow the lighting instructions in the "Lighting" stction to restart the water heater.
DISCHARGE PIPE
Failure to install and maintain a new properly listed tempera-
claim which might result from excessive temperature or pressure,
AWARNING
If the temperature.pressure relief valve on the appliance weeps or dischargesperiodically,this may be due to thermal
expansion. Your water heater may have a check valve installed in the water line or a water meter with a check
valve. Consult the Sears Service Center for further infurma- Do not plug the
Housekeeping
Vacuum around base of water heater for dust, dirt, and Linton a
regular basis.
Combustible materials such as clothing, cleaning materials, or flammable liquids, etc. must not be placed against or adjacent to the water heater.
To insure sufqcient ventilation and combustion air supply, prop- er clearances from the water heater must be maintained at all
time,$.
Service
Before calling for repair service, read the Start Up Conditions
and Operational Conditions found in the Troubleshooting Guide of this manual.
If a condition persists or you are uncertain about the operation of the water heater, let a qualified person check it out.
Contact SEARS Repair Services at
21