Installation Instructions (cont'd)
Temperature-Pressure Relief Valve
&WARNING
At the time of manufacture this water heater was provided with a combination
Automatic Gas Shutoff Devices for Hot Water Supply Systems, and the latest edition of ANSI Z21.22 and the code
requirements of ASME. If replaced, the valve must meet the requirements of local codes,but not lessthan a combination
temperature and pressure relief valve certified as meeting the requirements for Relief Valves and Automatic Gas
Shutoff Devicesfor Hot Water SupplySystems, ANSI Z21.22 by a nationally recognized testing laboratory that maintains
periodic inspection of production of listed equipment or materials.
The valve must be marked with a maximum set pressurenot to exceed the marked hydrostatic working pressure of _le water heater (150 Ibs./sq. in.) and a discharge capacity not lessthan the water heater input rate as shownon the model rating plate. (Electric heaters, watts divided by 1000 x 3415 equal BTU/Hr. rate.)
Your localjurisdictionalauthority, while mandatingthe use of a
Compliance with such local requirements must be satisfied by the installer or end user of the water heater with a locally prescribed temperature.pressure relief valve installed in the
designatedopening in the water heater in place oftbe facto- ry furnishedvalve.
For safe operation of the water heater, the relief valve must not be removed from it'sdesignatedopening or plugged. The temperature.pressure relief valve must be installed directly into the fitting of the water heater designatedfor the relief valve. Position the valve downward and provide tubing
so that any dischargewill exit only within 6 inchesabove, or at any distance below the structural floor. Be certain that no
contact is made with any live electrical part. The discharge opening must not be blocked or reduced in size under any circumstances.Excessivelength, over 30 feet, or use of more than four elbows can cause restriction and reduce the dis- chargecapacity of the valve.
No valve or other obstruction is to be placed between the relief valve and the tank. Do not connect tubing directly to discharge drain unlessa 6" air gap is provided. To prevent bodily injury, hazard to life, or property damage, the relief valve must be allowed to dischargewater in quantities should circumstancesdemand. If the discharge pipe is not connect- ed to a drain or other suitable means, the water flow may causeproperty damage.
The DischargePipe:
Must not be smaller in size than the outlet pipe size oftbe valve, or haveany reducing couplingsor other restrictions.
Must not be pluggedor blocked.
Must be of material listed for hot water distribution.
Must be installed so as to allow complete drainage of beth
the
Must terminate at an adequate drain.
Must not haveany valve between the relief valve and tank.
AWARNING
The
extremalyhot
ffafter manually operating the valve, it fails to completely reset and continnesto release water, immediately dose the cold water inlet to the water heater, follow the draining instructions, and replace the
HOT | COLD |
SHUTOFF
VALVE
PRESSURE
RELIEF VALVE
"DISCHARGE PIPE
(Do not cap or plug)
[]
6" AIR | GAP |
FLOOR DRAIN |
|
RELIEF VALVEOPENING | |
At the time of manufacture,thiswater heater was prodded _ | a combinationtem- |
Yourlocal jurisdictionalauthori_, while mandatingthe use of a
rel_ vahe complyingwith ANSI Z21.22 andASME,may requirea va_ mo_el differont from the o_e furnishedwith _e water heater
Compliancewith suchlocalrequirements must be satisfiedby the installeror end user of the water heater with a
See
]2