important Safety instructions
The power supply cord with this air conditioner contains a current
detection device designed to reduce the risk of fire.
Please refer to the section 'Operation of Current Device'for details.
In the event that the power supply cord is damaged, it cannot be repaired, and it
must be replaced with a cord from the Product manufacturer.
Avoid fire hazard or electric
shock. Do not use an extension cord or an adaptor plug. Do not remove any prong from the power cord.
Grounding type wall
receptacle
circumstances, cut, i
remove, or bypass thej/ \,grounding prong.
Power supply cord
with 3=prong grounding plug and current detection device
Read all instructions before using this air conditioner.
For Your Safety
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. Read product labels for flammability and other warnings.
Prevent Accidents
To reduce the risk of fire, electrical shock, or injury to persons when using your air conditioner, follow basic precautions, including the following:
*Be sure the electrical service is adequate for the model you have chosen. This information can be found on the nameplate, which is located on the side of the cabinet.
*If the air conditioner is to be installed in a window, you will probably want to clean both sides of the glass first. If the window is a
*Be sure the air conditioner has been securely and correctly installed according to the separate installation instructions provided with this manual. Save this manual and the installation instructions for possible future use in removing or reinstalling this unit.
*When handling the air conditioner, be careful to avoid cuts from sharp metal fins on front and rear coils.
Electrical Information
The complete electrical rating of your new room air conditioner is stated on the serial plate. Refer to the rating when checking the electrical requirements.
Be sure the air conditioner is properly grounded. To minimize shock and fire hazards, proper grounding is important. The power cord is equipped with a
*Your air conditioner must be used in a properly grounded walt receptacle. If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker, have a qualified electrician install the proper receptacle.
*Do not run air conditioner without outside protective cover in place. This could result in mechanical damage within the air conditioner.
*Do not use an extension cord or an adapter plug.
READ THIS SECTION BEFORE ATTEMPTING TO OPERATE AIR CONDITIONER. Unit must be upright for one hour prior to operating.
Operation of Current | The power supply cord contains a current device that senses damage to the power cord. | |||||
To test your power | supply cord do the following: |
| ||||
Device | 1. | Plug in the | Air | Conditioner. |
| |
2. | The power | supply | cord will have TWO buttons on the plug head. Press | the TEST | ||
Plug in & |
| button. You wilt notice a click as the RESET button pops out. |
| |||
3. | Press the RESET | button. Again you wilt notice a click as the button engages. | ||||
press RESET | 4. | The power | supply | cord is now supplying electricity to the unit. (On some | products this | |
|
is also indicated by a light on the plug head).
NOTES:
•Do not use this device to turn the unit on or off.
. Always make sure the RESET button is pushed in for correct operation.
•The power supply cord must be replaced if it fails to reset when either the TEST button
is pushed, or it cannot be reset. A new one can be obtained by contacting Sears at
•If power supply cord is damaged, it CANNOT be repaired. It MUST be replaced by one obtained by contacting Sears at
4