Chapter 9: Configuring and Monitoring Alarms

Table 93: Summary of Key Alarm Output Fields (continued)

Field

Values

Additional Information

Received at

Date and time when the alarm condition was

 

 

detected.

 

Severity

Alarm severity—either major (red) or minor (yellow).

A major (red) alarm condition requires immediate action.

 

 

A minor (yellow) condition requires monitoring or

 

 

maintenance.

Subject

Brief synopsis of the alarm.

Clicking the alarm subject displays a detailed alarm message.

Detailed Alarm Message

Received at

Date and time when the failure was detected.

Severity

Alarm severity—either major (red) or minor (yellow).

Alarm Type

Category of the alarm:

 

Chassis—Indicates an alarm condition on the

 

chassis (typically an environmental alarm such

 

as temperature)

 

Configuration—Indicates that no rescue

 

configuration is set

 

ETHER—Indicates an alarm condition on an

 

Ethernet interface

 

DS3—Indicates an alarm condition on a DS3

 

interface

 

License—Indicates a software license

 

infringement

 

Serial—Indicates an alarm condition on a serial

 

interface

 

Services—Indicates an alarm condition on the

 

services module

A major (red) alarm condition requires immediate action. A minor (yellow) condition requires monitoring or maintenance.

Verifying the Alarms Configuration

To verify alarms configuration, perform the following task.

Displaying Alarm Configurations

Purpose Verify the configuration of the alarms.

Action From the J-Web interface, select

Configuration>View and Edit>View Configuration Text. Alternatively, from configuration mode in the CLI, enter the show chassis alarms command.

[edit]

user@host# show chassis alarms t3 {

Verifying the Alarms Configuration 175

Page 197
Image 197
Juniper Networks J-Series Verifying the Alarms Configuration, Displaying Alarm Configurations, Detailed Alarm Message